ISATIS GROUP Arikeh Sanat IsatisInstrumentation · Control · Safety

Analyzers & gas detection

Teledyne (Detcon) equipment, sourced and integrated

Teledyne Gas & Flame Detection is the safety instrumentation group of Teledyne Technologies, bringing together Detcon, Oldham, Simtronics and GMI. Detcon, its fixed detector line from Texas, supplies the 700 Series gas sensors installed on wellheads, gas plants and refinery units.

Teledyne (Detcon) logo
United States/Since 1983
Country
United States
Founded
1983
Part of
Teledyne Technologies
Known for
Fixed gas detectors and controllers

Related services

Related engineering guide

Fixed Gas Detection Systems: Sensor Selection, Placement and Testing

Read the guide

Have a part number?

Send the part number or datasheet and we reply with availability, lead time and price.

Send an enquiry

Detcon was founded in 1983 in The Woodlands, Texas, north of Houston, and built its name on industrial gas sensors and control electronics for oil and gas sites. In 2011 it was bought by Battery Ventures and placed in Industrial Safety Technologies alongside GMI, a platform that later added Oldham and Simtronics. Scott Safety, then part of Tyco, acquired Industrial Safety Technologies in 2015, Scott Safety moved to 3M in 2017, and in August 2019 Teledyne Technologies bought the 3M gas and flame detection business, which now trades as Teledyne Gas & Flame Detection. The Detcon range centres on the 700 Series: FP-700 catalytic bead sensors for combustible gas, IR-700 infrared sensors for hydrocarbons or CO2, TP-700 metal oxide semiconductor sensors, DM-700 electrochemical sensors for toxic gases and oxygen, and PI-700 photoionisation sensors for VOCs.

Replacing a fixed gas detector starts with the gas, the sensing principle and the signal it feeds. From the label and model code we read the sensor type, target gas, range and hazardous-area marking, then check them against the area classification drawing and the input card of the fire and gas system. A catalytic FP-700 needs oxygen to work and can be poisoned by silicones or lead compounds, so in such areas, or where the gas sits in an oxygen-poor stream, an IR-700 is often the better choice. For H2S we compare the electrochemical DM-700 with the TP-700 against site humidity, temperature and cross-sensitivity. Every 700 Series transmitter gives a 4-20 mA output and an RS-485 Modbus output. Where the loop is part of a SIL 2 function, the safety manual limits the certified path to the 4-20 mA signal, so we keep Modbus out of that loop.

We supply genuine Detcon sensor assemblies, replacement sensor cells, transmitter electronics, splash guards, calibration adapters and mounting hardware, together with Oldham detectors and controllers from the same Teledyne group, with traceable origin and the conformity certificates and hazardous-area approvals the project asks for. Electrochemical cells have a limited shelf life, so we check manufacture dates before dispatch and ship toxic sensors as close to installation as practical. When an older Detcon model is no longer built, we say so at the start and propose the current 700 Series equivalent, confirming the thread entry, wiring and alarm setpoints in the control system. Calibration gas of the right concentration and a matching flow adapter can be added to the order. Teledyne prices are given after the model codes and site data are reviewed.

Fixed gas detection equipment
Fixed gas detection equipment · ISATIS editorial illustration

Teledyne (Detcon) product families we supply

  • 01FP-700catalytic bead sensor for combustible gases
  • 02IR-700infrared sensor for hydrocarbons (LEL) or CO2
  • 03TP-700metal oxide semiconductor gas sensor
  • 04DM-700electrochemical sensors for toxic gases and oxygen
  • 05PI-700photoionisation sensor for VOCs
  • 06Oldham OLCT detectors and MX controllers from the same group

Typical applications

  • 1H2S and combustible gas detection at wellheads and gas plants
  • 2Fire and gas system loops in refinery and petrochemical units
  • 3CO2 and toxic gas monitoring in enclosed process buildings
  • 4Sensor replacement and recalibration on installed 700 Series heads

FAQ

Common questions about Teledyne (Detcon).

Is Detcon still a separate company?

No. Detcon passed through Industrial Safety Technologies, Scott Safety and 3M, and since 2019 it has been part of Teledyne Gas & Flame Detection. The 700 Series is still listed under the Teledyne name, and existing Detcon model codes remain the reference for spares.

Can the Modbus output of an IR-700 be used in a SIL 2 loop?

According to the IR-700 safety manual, the SIL 2 certification covers the standard 4-20 mA output only, and the Modbus interface should not be connected in SIL 2 applications. On non-safety installations Modbus can still be used for monitoring and diagnostics.

What do you need to quote a Detcon replacement?

The model code from the transmitter label, the target gas and range, the hazardous-area marking and the output the control system uses. A photo of the sensor head and junction box helps us confirm the thread size and mounting.

Analyzers & gas detection

Other brands in this discipline.

All brands
  • AMETEK logo
  • Servomex logo
  • Michell Instruments logo
  • Hach logo
  • Horiba logo
  • Thermo Fisher Scientific logo
  • Systech logo
  • Normalab logo
  • Oldham logo
  • Dräger logo
  • MSA Safety logo
  • Crowcon logo
  • Industrial Scientific logo
  • Det-Tronics logo
  • Simtronics logo
  • SIEGER logo
  • Kidde logo
  • Gent logo
  • C-TEC logo
  • Apollo logo
  • Hanna Instruments logo
  • SHAW Instruments logo

Send us your datasheets, P&IDs or tender documents.

We review them and reply with a technical and commercial proposal.

info@iow.ir +98 21 2205 5712 Request a quote