Analyzers & gas detection
SIEGER equipment, sourced and integrated
Sieger is a British gas detection brand founded by Joshua Sieger and now part of Honeywell's gas detection business. Many installed Sieger detectors and controllers carry the Zellweger Analytics or Honeywell Analytics name, and the current products are sold under Honeywell.
- Country
- United Kingdom
- Founded
- 1959
- Part of
- Honeywell
- Known for
- Fixed gas detectors
Related services
Related engineering guide
Fixed Gas Detection Systems: Sensor Selection, Placement and Testing
Read the guideHave a part number?
Send the part number or datasheet and we reply with availability, lead time and price.
Send an enquiryJoshua Sieger founded the business in the United Kingdom in 1959, and Honeywell credits him with inventing the first reliable catalytic bead sensor for flammable gas. The company traded as J&S Sieger and in 1979 was acquired by the Zellweger group, becoming part of Zellweger Analytics. Honeywell agreed to buy Zellweger Analytics in 2005 and renamed it Honeywell Analytics within its life safety business. Sieger is therefore a legacy name: the products it gave rise to are now made and sold as Honeywell gas detection. Well-known lines from this history include the Searchpoint Optima Plus point infrared hydrocarbon detector, the Searchline Excel open path infrared detector, which Honeywell describes as a standard in open path flammable gas detection since 1998, the Series 3000 transmitters for toxic gas and oxygen, and the System 57 modular fire and gas control system. Current open path models include the Searchline Excel Plus and Searchline Excel Edge, and the Sensepoint XCD family covers fixed toxic, oxygen and flammable gas.
Replacing a Sieger detector means matching both the sensor and the system it reports to. For catalytic heads we check the gas, the LEL range and the calibration gas used, and whether silicones or other poisons are present at the site. For a Searchpoint Optima Plus we confirm the target gas calibration, since an infrared detector set up for methane will not read propane correctly, and the 4-20 mA levels used for fault and inhibit. For Searchline Excel we record the path length, the transmitter and receiver model for that range and the mounting structure, because open path detectors need rigid mounts to stay aligned. Series 3000 transmitters take a sensor cartridge for the gas and range, and the MkII and MkIII versions differ, so the label is read before ordering. For System 57 we list each card type, channel setting and relay or voting logic.
We supply genuine Sieger legacy spares where they are still available and current Honeywell gas detection products, including detectors, sensor cartridges, open path transmitters and receivers, controller cards, mounting and weather protection parts and calibration kits, with traceable origin and the ATEX or IECEx documents the site requires. Many older Sieger and Zellweger Analytics models are no longer produced. When a part is discontinued we tell you at the start and propose the current Honeywell equivalent, for example a Searchline Excel Plus or Excel Edge for an older open path pair, or a Series 3000 MkIII in place of an earlier transmitter, after checking output signals, mounting and cable entries. For control systems we map each existing channel and relay before change-over. Prices are given after the label data and system configuration are reviewed.
SIEGER product families we supply
- 01Searchpoint Optima Pluspoint infrared hydrocarbon gas detector
- 02Searchline Excelopen path infrared gas detector
- 03Searchline Excel Plus and Excel Edgecurrent open path detectors, Edge 60 to 330 m
- 04Series 3000 MkII and MkIIItoxic gas and oxygen transmitters
- 05System 57modular fire and gas control system
- 06Sensepoint XCDfixed gas detector family with spare sensors
Typical applications
- 1Flammable gas detection along process unit boundaries with open path detectors
- 2Point hydrocarbon detection at pumps, compressors and flanges
- 3Toxic gas and oxygen monitoring in process buildings and analyzer shelters
- 4Fire and gas control panel upgrades with channel mapping
FAQ
Common questions about SIEGER.
Is Sieger still a separate brand?
No. Sieger became part of Zellweger Analytics in 1979, and Honeywell bought Zellweger Analytics in 2005 and renamed it Honeywell Analytics. The products are now sold as Honeywell gas detection, although many installed units still carry the Sieger name.
Can a Series 3000 replace an older Series 2000 transmitter?
Series 3000 transmitters were designed so they can be retrofitted in place of Series 2000 units. We still check the gas, range, output and mounting of each point before supplying.
What do you need to quote Sieger or Honeywell gas detection spares?
The model and part number from the label, the gas and range, the certification marking, and the controller or DCS input the detector connects to. For open path detectors, the path length as well.
Analyzers & gas detection
Other brands in this discipline.
Send us your datasheets, P&IDs or tender documents.
We review them and reply with a technical and commercial proposal.
info@iow.ir +98 21 2205 5712 Request a quote