Analyzers & gas detection
Dräger equipment, sourced and integrated
Dräger is a German safety and medical technology company. In process plants it is known for fixed and portable gas detection, breathing apparatus and Dräger-Tubes.
- Country
- Germany
- Founded
- 1889
- Known for
- Gas detectors and breathing apparatus
Related services
Related engineering guide
Fixed Gas Detection Systems: Sensor Selection, Placement and Testing
Read the guideHave a part number?
Send the part number or datasheet and we reply with availability, lead time and price.
Send an enquiryDräger was founded in Lübeck in 1889 and is still run from there by Drägerwerk, with the founding family involved. Its safety division covers fixed gas detectors, portable monitors, respiratory protection and gas detection tubes. In our plants Dräger Polytron electrochemical and catalytic heads and PIR infrared detectors are part of the fire and gas system around compressors, pump rows and process areas, while X-am and Pac portables travel with operators and permit holders. PSS breathing apparatus is standard kit for emergency response and confined space work in refineries and gas plants.
For fixed detection we start from the fire and gas philosophy and the gas dispersion study, then set detector type, location and alarm levels. Catalytic sensors can be poisoned by silicones and need oxygen, so for many hydrocarbon duties we prefer infrared. Toxic sensors such as H2S have a finite life, and we plan replacement intervals. We wire detectors to the F&G controller, check 4-20 mA ranges and fault levels, and bump test and calibrate each head with certified gas during commissioning.
We supply genuine Dräger detectors, sensors, portables, calibration adaptors and breathing apparatus with traceable origin, quoting from part numbers or your datasheet. Spare sensors have a shelf life, so we time deliveries to your maintenance schedule. Where older Polytron 2 or Polytron 7000 units are out of production we propose the current Polytron 8000 equivalent. Standard items arrive within weeks; certified systems may take longer.
Dräger product families we supply
- 01Polytron 8000 seriesfixed toxic, oxygen and flammable gas transmitters
- 02PIR 7000infrared flammable gas detectors
- 03REGARD 7000gas detection control systems
- 04X-am 2800, 5800 and 8000portable multi-gas monitors
- 05Pac 6500 and 8000single-gas personal monitors
- 06X-zone 5500transportable area monitors
- 07PSS 7000self-contained breathing apparatus
- 08Dräger-Tubescolorimetric gas detection tubes
Typical applications
- 1Fixed H2S and hydrocarbon detection on sour gas plants
- 2Confined space entry monitoring during turnarounds
- 3Breathing apparatus for emergency response teams
- 4Toxic gas detection in pharmaceutical solvent areas
FAQ
Common questions about Dräger.
Infrared or catalytic detectors for hydrocarbons?
Infrared detectors do not need oxygen, are not poisoned by silicones and fail safe, so we prefer them for most process areas. Catalytic beads still suit gases that infrared cannot see, such as hydrogen. We choose per gas and area.
Do you calibrate Dräger gas detectors?
Yes. We bump test and calibrate fixed and portable detectors with certified gas, record the results and replace sensors at the end of their life. We can also supply calibration adaptors and gas so your team can do routine checks.
Can new Dräger detectors connect to our existing F&G system?
In most cases yes, through 4-20 mA or HART. We check the input cards, fault current levels and power budget of the existing controller and adjust the configuration where needed.
Analyzers & gas detection
Other brands in this discipline.
Send us your datasheets, P&IDs or tender documents.
We review them and reply with a technical and commercial proposal.
info@iow.ir +98 21 2205 5712 Request a quote