Analyzers & gas detection
C-TEC equipment, sourced and integrated
C-TEC is a British manufacturer of fire alarm control panels and life safety systems based in Wigan. Its ZFP and XFP addressable panels, CAST devices and emergency voice communication systems are used in commercial, public and industrial buildings.
- Country
- United Kingdom
- Founded
- 1981
- Known for
- Fire alarm control panels
Related services
Related engineering guide
How to Read an Instrument Order Code Before Requesting a Spare
Read the guideHave a part number?
Send the part number or datasheet and we reply with availability, lead time and price.
Send an enquiryC-TEC is the trading name of Computionics Limited. The company was established in 1981, started in a small office in Wigan and now operates from Challenge Way, Martland Park, in Wigan, with a research and development site in Mawdesley, Lancashire. It describes itself as the UK's largest independent manufacturer of life safety systems and says it trades in more than 70 countries. Its fire range covers conventional panels; the XFP family of networkable analogue addressable panels; the ZFP touchscreen addressable panels in 2 to 8 loop versions; and CAST, short for C-TEC Addressable System Technology, its own protocol with detectors, sounders and interface devices designed and made in the UK. Beyond fire detection the company makes EVC emergency voice communication systems for refuge areas, the Quantec addressable call system and 800 Series call devices for care buildings, hearing loop systems, the Hush residential fire system and the EVAC-ALERT evacuation alert system.
The order code on an XFP panel tells us its protocol, so we read it before anything else. The suffix after the slash identifies the detector protocol: /X for Apollo XP95 and Discovery devices, /H for Hochiki ESP devices and /CA for C-TEC CAST devices, while an E in the code, as in XFP501E, marks the 16 zone single-loop model. Devices of the wrong protocol will not communicate with the panel, so loop devices are always selected to match the suffix. For ZFP panels we confirm the loop count, the networking arrangement (each networked main panel needs a ZHN network card on RS485) and any repeaters or gateways. For EVC systems we check the outstation type, such as the EVC302 hands-free units in surface or flush and in green or stainless steel, the cable type and the number of lines on the master. Battery standby time and the cause and effect matrix are reviewed before the order.
We supply genuine C-TEC panels, CAST and compatible loop devices, network cards, repeaters, EVC outstations and masters, Quantec and 800 Series call devices and spare PCBs, with traceable origin and EN 54 documentation where it applies. For an existing system we work from the panel code and suffix, the software version and the device list, so replacements suit the loop protocol and the panel configuration. When an XFP or older C-TEC panel needs to be replaced, we propose a current panel that keeps the existing field devices where the protocol allows it, and we say clearly when devices also need to change. Spares for panels installed in plant buildings and control rooms are grouped so a site can keep a sensible stock of PCBs, batteries and detectors. A quotation follows once the panel codes, protocols and device counts have been confirmed.
C-TEC product families we supply
- 01ZFPtouchscreen addressable fire panels, 2 to 8 loops
- 02XFPnetworkable analogue addressable fire panels
- 03CASTC-TEC addressable protocol with detectors, sounders and interfaces
- 04Conventional fire alarm control panels
- 05EVCemergency voice communication systems for refuge areas
- 06Quantec and 800 Seriescall systems for care buildings
- 07EVAC-ALERTevacuation alert system
- 08Hearing loop systems
Typical applications
- 1Addressable fire detection in offices, schools and public buildings
- 2Fire detection in plant buildings, workshops and control rooms
- 3Refuge area voice communication for disabled evacuation
- 4Call systems in hospitals, clinics and care homes
FAQ
Common questions about C-TEC.
What does the suffix on an XFP panel code mean?
It identifies the detector protocol: /X for Apollo XP95 and Discovery, /H for Hochiki ESP and /CA for C-TEC CAST. Loop devices must match this suffix to communicate with the panel.
Can a C-TEC panel be replaced without changing the detectors?
Often yes, if the new panel runs the same protocol as the existing devices. We check the panel code, suffix and device list first and say clearly if devices also need replacing.
What do you need to quote C-TEC equipment?
The full panel code with its suffix, the software version, the number of loops, the device list per loop and, for EVC or call systems, the number and type of outstations.