ISATIS GROUP Arikeh Sanat IsatisInstrumentation · Control · Safety

Analyzers & gas detection

Oldham equipment, sourced and integrated

Oldham is a French maker of fixed gas detectors and gas detection controllers, produced in Arras in northern France and today part of Teledyne Gas & Flame Detection. Its detector and controller systems watch for flammable gas, toxic gas and oxygen depletion in ATEX zones.

Oldham logo
France/Since 1948
Country
France
Founded
1948
Part of
Teledyne Technologies
Known for
Fixed gas detectors and controllers

Related services

Related engineering guide

Fixed Gas Detection Systems: Sensor Selection, Placement and Testing

Read the guide

Have a part number?

Send the part number or datasheet and we reply with availability, lead time and price.

Send an enquiry

Oldham's roots are in monitoring coal mine atmospheres, and the business later moved into surface industries. Its Arras site in the Hauts-de-France region has produced gas detection equipment since 1948 and remains the brand's headquarters and plant. Ownership has changed several times: Industrial Scientific acquired Oldham S.A. in 2006 and sold the fixed detection business to Industrial Safety Technologies in 2013, Scott Safety bought Industrial Safety Technologies in 2015, and 3M acquired Scott Safety in 2017. Since August 2019 Oldham has belonged to Teledyne Gas & Flame Detection, where the Arras operation trades as Teledyne Oldham Simtronics. The range is built as a system: OLCT detectors such as the digital OLCT 10N, the OLCT 80 field detector-transmitter, the OLCT 100 and the OLCT 700 and 710, wired to MX controllers including the MX 16, MX 32v2, MX 43 and MX256.

With Oldham the detector and the controller have to be selected together. On a digital line, OLCT 10N detectors share one cable and each carries an address, so a replacement must suit the controller and its line configuration; the MX 43 can take up to 32 digital detectors spread over 8 lines. Before replacing a head we read the part number, gas, range and ATEX marking from the label and check the controller channel settings, alarm thresholds and relay assignments, because a new sensor with a different range will misreport unless the channel is changed too. For analogue 4-20 mA detectors we confirm cable length and supply voltage at the head. Where an old controller is being replaced, we map every channel and relay to the new unit before the old one is removed, so the shutdown and ventilation logic stays the same.

We supply genuine Oldham detectors, replacement sensor cells, controllers, relay and output modules, calibration kits and accessories, with traceable origin and the ATEX and conformity documents the site requires. Calibration gas cylinders and the correct flow adapter for each detector type can be included so new heads are tested at start-up. When a detector or controller model is discontinued, we tell you at the start and propose the current Teledyne equivalent, checking that the digital protocol, mounting and cable entries fit the existing installation. For large retrofits we list each tag with its gas, range and controller channel so nothing is mixed up on site. Oldham prices are given after the label data and controller configuration are reviewed.

Fixed gas detection equipment
Fixed gas detection equipment · ISATIS editorial illustration

Oldham product families we supply

  • 01OLCT 10Ndigital gas detector for MX controller lines
  • 02OLCT 80field gas detector-transmitter for ATEX zones
  • 03OLCT 100fixed gas detector
  • 04OLCT 700 and OLCT 710fixed gas detectors
  • 05MX 43analogue and digital controller for up to 32 detectors
  • 06MX 16, MX 32v2 and MX256gas detection controllers

Typical applications

  • 1Flammable gas detection in compressor and pump houses
  • 2Toxic gas and oxygen depletion monitoring in process buildings
  • 3Controller replacement with channel and relay mapping
  • 4Sensor cell replacement and calibration on installed OLCT heads

FAQ

Common questions about Oldham.

Can an OLCT 10N be connected to any controller?

No. The OLCT 10N is a digital detector meant for Oldham controllers; depending on the manual revision, compatible units include the MX 43, MX 32v2, MX 16 and MX256. We confirm the controller model and firmware before supplying detectors.

Who owns Oldham today?

Oldham is part of Teledyne Gas & Flame Detection, owned by Teledyne Technologies since August 2019. It is still made in Arras, France, where the operation trades as Teledyne Oldham Simtronics.

What do you need to quote Oldham detectors?

The part number from the detector label, the gas and range, the ATEX marking and the controller model the detector connects to. For controllers, the number of channels, relays and outputs in use.

Analyzers & gas detection

Other brands in this discipline.

All brands
  • AMETEK logo
  • Servomex logo
  • Michell Instruments logo
  • Hach logo
  • Horiba logo
  • Thermo Fisher Scientific logo
  • Systech logo
  • Normalab logo
  • Teledyne (Detcon) logo
  • Dräger logo
  • MSA Safety logo
  • Crowcon logo
  • Industrial Scientific logo
  • Det-Tronics logo
  • Simtronics logo
  • SIEGER logo
  • Kidde logo
  • Gent logo
  • C-TEC logo
  • Apollo logo
  • Hanna Instruments logo
  • SHAW Instruments logo

Send us your datasheets, P&IDs or tender documents.

We review them and reply with a technical and commercial proposal.

info@iow.ir +98 21 2205 5712 Request a quote