ISATIS GROUP Arikeh Sanat IsatisInstrumentation · Control · Safety

Analyzers & gas detection

Horiba equipment, sourced and integrated

HORIBA is a Japanese maker of analytical and measuring instruments with its head office in Kyoto. On refineries, power plants and petrochemical sites it is known for stack gas analyzers, multi-component process gas analyzers, ambient air monitors and industrial pH meters.

Horiba logo
Japan/Since 1945
Country
Japan
Founded
1945
Known for
Gas analyzers and emissions monitoring

Related services

Related engineering guide

Analyzer Sampling System Design: 7 Principles for Reliable Measurement

Read the guide

Have a part number?

Send the part number or datasheet and we reply with availability, lead time and price.

Send an enquiry

Masao Horiba started the business in Kyoto in October 1945 as Horiba Radio Laboratory, and the company was incorporated in 1953. Early work on pH meters led the company into gas analysis, and HORIBA Ltd. is today a listed Japanese group that still has its head office in Kyoto. The group works in automotive testing, semiconductors, scientific instruments and process and environmental measurement, and it is the last of these that appears on oil, gas and power sites. The main products there are the ENDA-5000 series stack gas analysis system for continuous emission monitoring of NOx, SO2, CO, CO2 and O2, the VA-5000 multi-component gas analyzer with its wall-mounted VA-5000WM version and the VS-5000 sample conditioning unit, the PG-300 series portable gas analyzers, the AP-370 series ambient monitors such as the APNA-370 for nitrogen oxides and the APSA-370 for sulphur dioxide, and the HP-480 family of industrial pH meters.

A HORIBA gas analyzer is part of a sampling chain, so we review the whole chain and not only the cabinet. For an ENDA-5000 or VA-5000 we record each measured component and its range, the detector type in each module (cross-modulated NDIR for the infrared gases and a magneto-pneumatic detector for oxygen), the zero and span gas concentrations and the analog outputs and alarm contacts wired to the DCS or emissions computer. HORIBA designs the ENDA-5000 for dry sampling with an electric cooler, sample gas at 250 °C or lower and dust at 0.1 g/Nm3 or less, so we check the probe, heated line, filters and cooler against these limits before a replacement is ordered. For HP-480 pH meters we confirm the electrode and holder type, temperature compensation, cable length, control output option and the mounting. Where a single module fails, we match the module code on its label rather than the analyzer model alone.

We supply genuine HORIBA analyzers, detector modules, sample conditioning parts such as pumps, filters and coolers, pH electrodes and holders, and spare boards, with traceable origin and the test report or calibration certificate issued for each instrument. Calibration gas of the right concentration for each range can be supplied with the analyzer so the system can be spanned at start-up. When an older HORIBA analyzer or rack is no longer produced, we say so at the start and compare it with the current ENDA-5000 or VA-5000 configuration, checking ranges, panel cut-out, signals and sample conditions so the change fits the existing shelter and wiring. For emission systems we also note which local approval or test the new configuration will need. HORIBA prices are given after the analyzer data and part codes have been reviewed.

Sensor and analytical transmitter
Sensor and analytical transmitter · ISATIS editorial illustration

Horiba product families we supply

  • 01ENDA-5000 seriesstack gas analysis system for continuous emission monitoring
  • 02VA-5000 and VA-5000WMmulti-component gas analyzers, 19-inch panel or wall mount
  • 03VS-5000sample gas conditioning unit for the VA-5000
  • 04PG-300 seriesportable gas analyzers
  • 05AP-370 seriesambient monitors including APNA-370 for NOx and APSA-370 for SO2
  • 06HP-480 seriesindustrial pH meters for effluent and process water

Typical applications

  • 1Continuous emission monitoring on boiler, heater and furnace stacks
  • 2Spot checks of combustion and process gas with portable analyzers
  • 3Ambient NOx and SO2 monitoring around plant boundaries
  • 4pH monitoring of effluent and process water

FAQ

Common questions about Horiba.

Can a VA-5000 replace an older HORIBA analyzer in the same panel?

Often it can. The VA-5000 mounts in a 19-inch panel and holds up to four detector modules in one case, but the components, ranges, output signals and sample conditioning have to be matched first. We compare the old analyzer data with the new configuration before ordering.

What sample conditions does the ENDA-5000 expect?

HORIBA specifies dry sampling with an electric cooler, sample gas at 250 °C or lower and dust of 0.1 g/Nm3 or less. Stacks outside these limits need extra filtration or cooling at the probe and in the sample line.

What do you need to quote HORIBA spare parts?

The analyzer model and serial number, the module or part code from the label, the measured components and ranges, and for pH meters the electrode and holder type. A photo of the nameplate is usually enough to start.

Analyzers & gas detection

Other brands in this discipline.

All brands
  • AMETEK logo
  • Servomex logo
  • Michell Instruments logo
  • Hach logo
  • Thermo Fisher Scientific logo
  • Systech logo
  • Normalab logo
  • Teledyne (Detcon) logo
  • Oldham logo
  • Dräger logo
  • MSA Safety logo
  • Crowcon logo
  • Industrial Scientific logo
  • Det-Tronics logo
  • Simtronics logo
  • SIEGER logo
  • Kidde logo
  • Gent logo
  • C-TEC logo
  • Apollo logo
  • Hanna Instruments logo
  • SHAW Instruments logo

Send us your datasheets, P&IDs or tender documents.

We review them and reply with a technical and commercial proposal.

info@iow.ir +98 21 2205 5712 Request a quote