Analyzers & gas detection
Kidde equipment, sourced and integrated
Kidde Fire Systems is an American maker of engineered fire suppression, detection and control systems for industrial, commercial and marine hazards, based in Ashland, Massachusetts. Since 2024 it has been part of KiddeFenwal, a stand-alone company backed by Pacific Avenue Capital Partners.
- Country
- United States
- Founded
- 1917
- Part of
- Pacific Avenue Capital Partners
- Known for
- Fire suppression and detection systems
Related services
Related engineering guide
How to Read an Instrument Order Code Before Requesting a Spare
Read the guideHave a part number?
Send the part number or datasheet and we reply with availability, lead time and price.
Send an enquiryThe Kidde Fire Systems and Kidde Fire Protection names trace back to Walter Kidde, who started the business in 1917. The industrial suppression and controls company, Kidde-Fenwal, Inc., was later part of Carrier. Kidde-Fenwal filed for Chapter 11 in May 2023 over firefighting foam claims, and on 2 July 2024 its assets were sold to an affiliate of Pacific Avenue Capital Partners. The business now trades as KiddeFenwal, headquartered in Ashland, Massachusetts, with the Kidde Fire Systems, Kidde Fire Protection and Fenwal Controls brands. Note that the Kidde name also appears on residential and commercial fire products from Kidde Global Solutions, a separate company formed when Lone Star Funds bought Carrier's fire business in December 2024. For industrial sites the main KiddeFenwal lines are HFC-227ea and Fluoro-K clean agent systems with ADS, ECS-500 and ECS-360 delivery platforms, NATURA systems, high-pressure CO2 and CARDOX low-pressure CO2, IND dry chemical systems, ARIES-SLX, ARIES-MLX and AEGIS-PHX panels and SmartOne detectors.
Suppression parts have to match the listed system design, so we work from the system documents and the cylinder and valve labels. For a clean agent or CO2 system we record the agent, cylinder size and fill weight, valve and actuator type (electric, pneumatic or manual), discharge hose and check valve parts, nozzle part numbers and the hydraulic calculation reference. Replacing a cylinder valve or nozzle with a part from a different system can change flow and discharge time, so we confirm each part against the design manual. For control panels we check whether the existing detectors are SmartOne devices on an ARIES loop, how many release, abort and manual release circuits are used, and the interface to the fire and gas system or DCS. For turbine enclosures and heaters we confirm the THERMOSWITCH or DETECT-A-FIRE set point and fixed or rate compensated type before ordering.
We supply genuine Kidde Fire Systems cylinders, valves, actuators, nozzles, hoses, control panels, detectors, modules and Fenwal heat detectors, with traceable origin, the certificate of conformity and, for pressure equipment, the cylinder test and fill records. Older Kidde, Fenwal Protection Systems and Chemetron panels and some legacy agents are no longer produced, because Kidde has merged these lines into one range and agent rules have changed in several markets. When a part is discontinued we tell you at the start and propose the current KiddeFenwal equivalent, for example an ARIES or AEGIS panel in place of an older releasing panel, checking loop devices, release circuits and the existing cylinder actuation. Refilling and recharging of agent cylinders depend on local approval and are planned with the site. Kidde prices are given after the system documents and label data are reviewed.
Kidde product families we supply
- 01HFC-227ea and Fluoro-Kclean agent suppression systems
- 02ADS, ECS-500 and ECS-360clean agent delivery platforms
- 03NATURA and NATURA-Microsuppression systems
- 04High-pressure CO2 and CARDOX low-pressure CO2 systems
- 05IND dry chemical systems for industrial hazards
- 06ARIES-SLX, ARIES-MLX and AEGIS-PHXdetection and releasing panels
- 07SmartOne detectors and modules, LHS linear heat sensing
- 08Fenwal THERMOSWITCH and DETECT-A-FIRE heat detectors
Typical applications
- 1Clean agent protection of control rooms, switchgear and analyzer shelters
- 2CO2 protection of gas turbine enclosures and generator packages
- 3Heat detection in turbine enclosures and fired equipment
- 4Releasing panel replacement with loop and circuit mapping
FAQ
Common questions about Kidde.
Who owns Kidde today?
Kidde Fire Systems belongs to KiddeFenwal, a stand-alone company acquired by an affiliate of Pacific Avenue Capital Partners in July 2024. Residential and commercial Kidde products come from Kidde Global Solutions, owned by Lone Star Funds since December 2024.
Can a Kidde cylinder valve or nozzle be swapped for a similar one?
Only when it is the same part number listed for that system. Valves, nozzles and hoses affect flow and discharge time, so we confirm each part against the system design manual and hydraulic calculation.
What do you need to quote Kidde suppression or panel parts?
The part numbers from the cylinder, valve and panel labels, the agent and fill weight, the system drawings or calculation reference, and for panels the detector types and number of release circuits.
Analyzers & gas detection
Other brands in this discipline.
Send us your datasheets, P&IDs or tender documents.
We review them and reply with a technical and commercial proposal.
info@iow.ir +98 21 2205 5712 Request a quote




