ISATIS GROUP Arikeh Sanat IsatisInstrumentation · Control · Safety

Analyzers & gas detection

Gent equipment, sourced and integrated

Gent is the Leicester-based fire detection and alarm brand of Honeywell. Its Vigilon addressable panels and S-Quad multi-function devices are used in hospitals, universities, airports, commercial buildings and industrial sites, mainly where large networked systems are needed.

Gent logo
United Kingdom/Since 1872
Country
United Kingdom
Founded
1872
Part of
Honeywell
Known for
Addressable fire alarm systems

Related services

Related engineering guide

How to Read an Instrument Order Code Before Requesting a Spare

Read the guide

Have a part number?

Send the part number or datasheet and we reply with availability, lead time and price.

Send an enquiry

The company was founded by John Thomas Gent in Leicester, UK, and is generally dated to 1872, when it began as a maker of electric clocks. It was taken over by Chloride in 1975, sold to the MK Electric Group in 1983 and acquired by Caradon, later Novar, in 1993. Honeywell bought Novar in 2005 and the business has since traded as Gent by Honeywell and Honeywell Gent, with Novar Systems Ltd as the legal entity. In January 2022 it moved to Carlton Park in Leicester. The current range includes the Vigilon Plus networked panel in 4 and 6 loop versions, the Vigilon Compact Plus panel with up to two loop cards, the single-loop Nano, the S-Quad range of sensors, sounders, voice sounders and visual alarm devices, the S-Quad Self-Test detectors, S-Cubed sounders, Xenex conventional panels and Plexus wireless devices.

Gent systems are matched by protocol and panel generation, so we start from the panel type and the software version shown on the panel or in the commissioning file. Older Gent systems such as the 3400 and 34000 series use earlier protocols, and not every new device or loop card works with them: the current Vigilon loop card is not available in the BS protocol used by 3400 panels, and the S-Quad adapter base is not supported on 34000 or older panels. On Vigilon Plus panels each loop takes up to 200 devices, with lower limits when sensor sounders or sensor VADs are used, and EN 54-2 caps a 4 or 6 loop panel at 512 sensors and call points. A loop card can carry up to 100 S-Quad sensor sounder VADs to EN 54-23 over a loop of up to 2000 m. We check these limits, the battery calculation and the cause and effect matrix before adding devices to a live system.

We supply genuine Gent panels, loop cards, network and repeater panels, S-Quad devices and bases, call points, interface units and replacement batteries, with traceable origin and the EN 54 certificates the project needs. For replacement work we ask for the device part number from the label, a photo of the panel and its software level, and the loop count, so the new devices are addressed and programmed to suit the existing configuration. When a model has been withdrawn, we say so at the start and propose the current device that runs on the same panel generation, or explain what panel upgrade is needed. Detectors used in dusty or humid industrial areas are reviewed against the environment so the sensing mode and the alarm thresholds suit the space. A quotation is prepared once the panel type, protocol and device list are confirmed.

Sensor and analytical transmitter
Sensor and analytical transmitter · ISATIS editorial illustration

Gent product families we supply

  • 01Vigilon Plusnetworked addressable panel in 4 and 6 loop versions
  • 02Vigilon Compact Plusaddressable panel with up to two loop cards
  • 03Nanosingle-loop addressable panel
  • 04S-Quadmulti-criteria sensors, sounders, voice sounders and VADs
  • 05S-Quad Self-Testdetectors with built-in functional testing
  • 06S-Cubedsounders and voice sounders
  • 07Xenexconventional fire alarm panels
  • 08Plexuswireless fire detection devices

Typical applications

  • 1Networked fire detection in hospitals, campuses and airports
  • 2Fire alarm extensions and device replacement on existing Vigilon systems
  • 3Voice sounders and visual alarms in large public buildings
  • 4Fire detection in plant control rooms, offices and warehouses

FAQ

Common questions about Gent.

Can S-Quad devices be fitted to an old Gent 34000 panel?

Not directly. The S-Quad adapter base is not supported on 34000 or older panels, so we check the panel generation first and propose either compatible devices or a panel upgrade.

How many devices can a Vigilon Plus loop take?

Up to 200 devices per loop, with lower limits for sensor sounders and sensor VADs, and EN 54-2 limits a 4 or 6 loop panel to 512 sensors and call points. We confirm the loop load before adding devices.

What do you need to quote Gent equipment?

Device part numbers from the labels, the panel type and software level, the number of loops and the device count per loop. For a new system, the floor plans and the fire strategy are needed.

Analyzers & gas detection

Other brands in this discipline.

All brands
  • AMETEK logo
  • Servomex logo
  • Michell Instruments logo
  • Hach logo
  • Horiba logo
  • Thermo Fisher Scientific logo
  • Systech logo
  • Normalab logo
  • Teledyne (Detcon) logo
  • Oldham logo
  • Dräger logo
  • MSA Safety logo
  • Crowcon logo
  • Industrial Scientific logo
  • Det-Tronics logo
  • Simtronics logo
  • SIEGER logo
  • Kidde logo
  • C-TEC logo
  • Apollo logo
  • Hanna Instruments logo
  • SHAW Instruments logo

Send us your datasheets, P&IDs or tender documents.

We review them and reply with a technical and commercial proposal.

info@iow.ir +98 21 2205 5712 Request a quote