Control, safety & networks
MTL equipment, sourced and integrated
Start with the number on the cabinet module. For a 4–20 mA transmitter, compare the MTL5042 and MTL5043 by wiring and output count. For switch inputs or solenoid outputs, the MTL4016 and MTL5022 serve different field devices.
- Country
- United Kingdom
- Founded
- 1971
- Part of
- Eaton
- Known for
- Intrinsic safety barriers and isolators
Related services
Related engineering guide
Hazardous Area Classification and Ex Equipment: Zones, Gas Groups and Protection Concepts
Read the guideHave a part number?
Send the part number or datasheet and we reply with availability, lead time and price.
Send an enquiryMTL started in 1971 as Measurement Technology Ltd in Luton, England, and built its name on the shunt-diode zener barrier. Cooper Industries bought it in 2008 and Eaton acquired Cooper in 2012, so MTL is now an Eaton brand. In a rack room, MTL hardware sits between the DCS or ESD I/O and the field cabling of Zone 0 and Zone 1 instruments: DIN-rail isolators of the MTL5500 series, backplane-mounted MTL4500 isolators, MTL7700 zener barriers, and surge protection for signal and power lines. Older plants still run the MTL5000 series, including repeater power supplies such as the MTL5042 for 4–20 mA HART transmitters.
Most of our MTL work is loop design and replacement. For each loop we match the isolator or barrier to the field device certificate with the entity check (Uo, Io and Po against Ui, Ii and Pi, and Co and Lo against the device plus the cable) and record it in the descriptive system document. When an MTL5000 module fails, we choose the current equivalent and check terminal layout, supply and any change in safety parameters before the swap. On backplane systems we confirm the carrier, the DCS interface board and the HART multiplexer set-up, so asset management software still reaches the field devices.
We source MTL isolators, barriers and surge protectors as genuine product with traceable origin and quote against the exact part number, since channel count, supply and output type can change with a single digit. Older MTL5000 and MTL3000 modules are getting harder to find. We check stock first and, when the original is no longer available, offer the current module with a written cross-reference. MTL prices are given on enquiry after the part list is reviewed.
MTL product families we supply
- 01MTL5500DIN-rail intrinsic safety isolators
- 02MTL4500backplane-mounted isolators for DCS and ESD cabinets
- 03MTL7700shunt-diode zener barriers
- 04MTL5000earlier DIN-rail isolators and repeater power supplies
- 05MTL4850HART multiplexer for asset management
- 06Surge protection for field instruments and signal lines
- 07Fieldbus power conditioners and device couplers
Typical applications
- 1Isolating 4–20 mA HART transmitters in Zone 0 and Zone 1
- 2ESD and fire and gas loops in marshalling cabinets
- 3Surge protection for tank farm and pipeline instruments
- 4Foundation fieldbus segments in hazardous areas
Which MTL module matches the field device?
For a transmitter, record the wire count and the number of systems receiving the signal. For a switch or solenoid, record the field-device reference. If HART communication matters, include the marking on the installed module.
Buying guides for this equipment
Listed stock references
Check the model and quantity on each item. Request confirmation of availability and delivery for your order.
- MTL5043Repeater power supply, dual output, 4–20 mA, for 2-wire transmitters25 pcs
- MTL7728+Shunt-diode (zener) safety barrier, single channel30 pcs
- MTL7778+MTL barrier reference for nameplate verification10 pcs
- MTL5042Repeater power supply, 4–20 mA, for 2- or 3-wire transmitters2 pcs
- MTL5022Loop-powered solenoid/alarm driver, IIB3 pcs
- MTL4016Switch/proximity detector interface, 2-channel, relay output with line fault detection2 pcs
FAQ
Common questions about MTL.
What replaces an MTL5042 or another MTL5000 module?
In most cases a module from the MTL5500 series is the current equivalent, but terminal numbering, supply range and safety parameters are not always identical. Send the full part number of the existing module and the field device it serves, and we confirm the replacement and recheck the intrinsic safety loop.
Should I use a zener barrier or a galvanic isolator?
A zener barrier is simple and low in cost but needs a high-integrity intrinsically safe earth, and it can upset loops with earthed field devices. A galvanic isolator needs no IS earth and fully separates the circuits, which is why most new projects use isolators. We look at the existing earthing, loop types and cabinet space before recommending one.
Can MTL isolators pass HART signals?
The HART-compatible models pass the digital signal in both directions, so a handheld communicator or an asset management system can talk to the transmitter. Not every model is HART-transparent, so check the data sheet. On backplane systems a HART multiplexer such as the MTL4850 can collect the data for the whole cabinet.
Control, safety & networks
Other brands in this discipline.
Send us your datasheets, P&IDs or tender documents.
We review them and reply with a technical and commercial proposal.
info@iow.ir +98 21 2205 5712 Request a quote