How zones, gas groups and temperature classes are set, how Ex d, Ex e, Ex i and Ex p compare, and what to check when installing and inspecting Ex equipment.
Every instrument, motor and junction box installed in a hazardous area is a potential ignition source. Ex equipment is designed so that it cannot ignite the surrounding atmosphere, but only when it matches the area it is installed in and is installed and maintained the way its certificate assumes. Most findings in Ex inspections are not defective equipment; they are the wrong protection concept for the zone, the wrong gas group or temperature class, or a gland, cover or barrier that no longer matches the certificate.
This guide explains how zones, gas groups and temperature classes are set, what the main protection concepts are, and what to check when selecting, installing and inspecting Ex equipment.
Area classification: zones
Area classification under IEC 60079-10-1 divides a plant into zones according to how often and how long an explosive gas atmosphere is expected to be present:
- Zone 0: present continuously or for long periods, for example inside a tank above the liquid surface.
- Zone 1: likely to occur in normal operation from time to time, for example around pump seals, sample points and vents.
- Zone 2: not likely in normal operation and, if it occurs, only for a short time, for example around flanges and valves that leak only under fault conditions.
Dust atmospheres use Zones 20, 21 and 22 under IEC 60079-10-2 in the same way. Classification is a process safety study, based on the release sources, release rates and ventilation, and its drawings are the input for every Ex selection that follows. North American installations may instead use the Class and Division system, which maps roughly but not exactly onto zones.
Gas groups and temperature classes
Two more properties of the atmosphere decide which equipment is acceptable:
- Gas group reflects how easily a gas ignites and how readily a flame passes through a gap. Group IIA covers propane and most hydrocarbons, IIB covers ethylene, and IIC covers hydrogen and acetylene. Equipment rated IIC may be used in IIB and IIA areas, not the other way round.
- Temperature class limits the maximum surface temperature of the equipment, from T1 (450 °C) to T6 (85 °C). It must be below the auto-ignition temperature of every gas that may be present. Hydrogen sulphide, for example, needs at least T3.
Equipment Protection Level (EPL) ties it together: Ga equipment is suitable for Zone 0, Gb for Zone 1 and Gc for Zone 2. A marking such as Ex db IIB T4 Gb therefore says the protection concept, gas group, temperature class and the zone the equipment may be used in.
Protection concepts compared
| Concept | Code | Principle | Typical use |
|---|---|---|---|
| Flameproof enclosure | Ex d | An internal explosion is contained and cannot pass through the flame paths | Motors, junction boxes, transmitter housings, lighting |
| Increased safety | Ex e | Sparks and hot surfaces are prevented by construction | Terminal boxes, motors, light fittings |
| Intrinsic safety | Ex i (ia, ib, ic) | The energy in the circuit is limited below what could ignite the gas | Transmitters, switches, solenoids, fieldbus segments |
| Pressurisation | Ex p | Clean air or inert gas inside the enclosure keeps the gas out | Analyzer shelters, control panels, large motors |
| Encapsulation | Ex m | Ignition sources are sealed in compound | Solenoid coils, small electronics |
| Non-sparking (Zone 2) | Ex nA / ec | Equipment that does not spark or run hot in normal operation | Zone 2 motors and lighting |
Intrinsic safety in practice
Intrinsic safety is the usual choice for instrumentation because it allows live work on the loop and needs no heavy enclosures. It is a system concept, not a property of the field device alone. The barrier or isolator in the safe area and the field device must be compared using their entity parameters: the barrier’s Uo, Io and Po must not exceed the device’s Ui, Ii and Pi, and the cable capacitance and inductance plus the device’s Ci and Li must stay within the Co and Lo the barrier allows. This check, documented as a loop descriptive system document, is the evidence that the loop is safe. Galvanic isolators avoid the need for a high-integrity earth that zener barriers require, which is why they are now the common choice. Blue cables and separate, marked terminals keep intrinsically safe circuits apart from others.
Installation details that decide compliance
- Cable glands must carry their own Ex certificate for the concept of the enclosure; a flameproof enclosure needs Ex d glands, and barrier glands where the standard requires them.
- Unused entries are closed with certified stopping plugs, never with the plastic dust caps fitted for transport.
- Flame paths on Ex d covers must be clean, undamaged and free of paint or gaskets that were not part of the certificate.
- Earthing and bonding follow IEC 60079-14, including the potential equalisation that prevents sparks between metal parts.
- Modifications such as drilling an extra entry or fitting a different component invalidate the certificate unless done under the manufacturer’s control.
Inspection and maintenance
IEC 60079-17 requires an initial detailed inspection before commissioning and periodic inspections afterwards, at visual, close or detailed level, normally at intervals not exceeding three years. An Ex register listing each item with its certificate, marking and location makes those inspections and any later replacement much easier. Repairs are covered by IEC 60079-19 and must restore the equipment to its certified condition. People who select, install or inspect Ex equipment should be competent for the task; schemes such as IECEx CoPC certify that competence.
Frequently asked questions
Is ATEX equipment acceptable where IECEx is required?
Not automatically. ATEX is the European legal framework and IECEx is an international certification scheme; both use the IEC 60079 standards, so many products carry both. Check which certificate the project specification and local regulations call for, and request it with the equipment.
Can a Zone 1 device be used in Zone 2?
Yes. Equipment suitable for a higher-risk zone can be used in a lower-risk one, provided the gas group and temperature class also suit the area. The reverse is never allowed.