ISATIS GROUP Arikeh Sanat IsatisInstrumentation · Control · Safety

Control, safety & networks

Moore Industries equipment, sourced and integrated

Moore Industries-International is an American maker of signal interface instruments, headquartered in North Hills, California. Its HART isolators, safety trip alarms and temperature transmitters are used in process control loops and safety instrumented systems.

Moore Industries logo
United States/Since 1968
Country
United States
Founded
1968
Known for
Signal conditioners and alarm trips

Related services

Related engineering guide

Industrial Instrument Calibration: Why, When and How

Read the guide

Have a part number?

Send the part number or datasheet and we reply with availability, lead time and price.

Send an enquiry

Moore Industries-International was founded in 1968 by Leonard W. Moore, who started it with three employees in a garage in California. In 1974 he built the headquarters in North Hills, where the company still manufactures all of its products. Moore Industries is privately held and not part of a larger group. The range focuses on the interface between field instruments and control systems: the STA safety trip alarm, compliant for SIL 2 and SIL 3 and usable as a single-loop logic solver; the SSX 2-wire and SST 4-wire safety series isolators and splitters, which pass HART data to asset management systems; the SPA2 programmable alarm trip; the THZ3 dual-input smart HART temperature transmitter, which can watch a thermocouple loop for resistance changes before the sensor fails; the HIM HART interface module, which reads HART digital variables and turns them into analog signals or alarms; and the NCS net concentrator system for distributed I/O.

Moore model codes are long and descriptive: they list unit type, input, output, power supply, options and housing, so the code alone tells us the input range, number of relays and whether the unit mounts on a DIN rail or in a field enclosure. We read the full code from the label together with the calibration data, then match input type and range, output signal, power source and alarm configuration. For the SSX and SST we check the power arrangement, since the SSX is loop-powered and the SST is line-powered and can supply 24 V to a 2-wire transmitter. For the STA we confirm alarm setpoints, latching or non-latching relays, the fault alarm relay and the SIL level in the safety requirement specification. Where an HIM monitors HART variables we note that it reads only the digital signal and not the 4-20 mA loop, and plan how loss of signal will be handled in the control system.

We supply genuine Moore Industries isolators, splitters, alarm trips, temperature transmitters, HART interface modules and configuration cables, with traceable origin and the conformity, hazardous-area and functional safety documents the project requires. Units can be ordered configured to the setpoints, ranges and tag data on the instrument datasheet, and the settings can be checked with Moore configuration software before shipment. When an older model is discontinued, we state it at the start and propose the current equivalent, checking terminal layout, housing and approvals so loop drawing changes are known in advance. For safety loops we include the safety manual and failure data so the SIL verification can be updated with the new device. Moore Industries prices are given after the model codes and loop data are reviewed.

Rack and control modules
Rack and control modules · ISATIS editorial illustration

Moore Industries product families we supply

  • 01STASIL 2 and SIL 3 safety trip alarm
  • 02SSX and SSTsafety series HART isolators and splitters
  • 03SPA2programmable alarm trip
  • 04THZ3dual-input smart HART temperature transmitter
  • 05HIMHART interface module
  • 06NCSnet concentrator system

Typical applications

  • 1Trip and permissive functions in safety instrumented systems
  • 2HART isolation between field transmitters and DCS or SIS inputs
  • 3Temperature alarms on heaters, compressors and bearings
  • 4Reading HART secondary variables from multivariable transmitters

FAQ

Common questions about Moore Industries.

Can the STA replace a safety PLC in a small safety function?

For a single-loop function, Moore Industries describes the STA as a logic solver that can be used instead of a safety PLC. The SIL level, proof testing and diagnostics are still checked against the safety manual and the safety requirement specification.

What is the difference between the SSX and the SST?

The SSX is a 2-wire loop-powered isolator and the SST is a 4-wire line-powered unit that can also supply 24 V to a 2-wire transmitter. Both pass HART data, and in single use mode both are approved for SIS use up to SIL 2.

What do you need to quote Moore Industries units?

The full model code from the label, the input and output ranges, the power supply, the alarm setpoints and relay configuration and, for safety loops, the required SIL level. A copy of the instrument datasheet speeds up the review.

Control, safety & networks

Other brands in this discipline.

All brands
  • ABB logo
  • Siemens logo
  • Honeywell logo
  • Yokogawa logo
  • Emerson logo
  • Allen-Bradley logo
  • Rockwell Automation logo
  • Schneider Electric logo
  • HIMA logo
  • ICS Triplex logo
  • Foxboro logo
  • Beckhoff logo
  • Mitsubishi logo
  • Omron logo
  • Fuji Electric logo
  • Yaskawa logo
  • Pepperl+Fuchs logo
  • Phoenix Contact logo
  • Weidmüller logo
  • Turck logo
  • Banner Engineering logo
  • PR electronics logo
  • MOXA logo
  • Hirschmann (Belden) logo
  • Cisco logo
  • Advantech logo
  • Winsonic logo
  • Woodward logo
  • GE logo
  • Siemens Energy logo
  • Azbil logo
  • MTL logo
  • KEYENCE logo

Send us your datasheets, P&IDs or tender documents.

We review them and reply with a technical and commercial proposal.

info@iow.ir +98 21 2205 5712 Request a quote