PR electronics equipment, sourced and integrated

PR electronics is a Danish maker of signal conditioning devices, based in Rønde near Aarhus. Its temperature transmitters, isolators, intrinsically safe interfaces and universal transmitters sit in field heads and marshalling cabinets across process plants.

PR electronics logo
Denmark/Since 1974
Country
Denmark
Founded
1974
Known for
Signal isolators and temperature transmitters

Related services

Related engineering guide

Temperature Measurement: RTD or Thermocouple, Thermowells and Transmitters

Read the guide

Have a part number?

Send the part number or datasheet and we reply with availability, lead time and price.

Send an enquiry

PR electronics was founded in 1974 by Peter Rasmussen and has its headquarters in Rønde, Denmark. His son Kim Rasmussen took over as CEO and owner in 2009, and in 2023 the investment companies Kirk Kapital and AGIC Capital acquired the business, with management staying on as co-owners. The range covers temperature transmitters for head and rail mounting, such as the 5437 dual-input 2-wire HART 7 transmitter and the 3337 loop-powered HART 7 temperature converter; the 9100 series of intrinsically safe interfaces, including the 9106 HART transparent repeater and the 9113 temperature/mA converter; the 4100 series of multifunctional devices, including the 4116 universal transmitter with current, voltage and relay outputs; and the 4500 series detachable fronts, such as the 4510 display/programming front, which configure and monitor many of these devices.

A PR electronics device is identified by a four-digit model number and a letter suffix, and the suffix matters. On the 9106, for example, 9106B1A is a 1-channel repeater with a 27.5 V barrier while 9106B2A has a 25.3 V barrier, so the barrier voltage must suit the transmitter's minimum supply plus loop resistance. We read the full order code, input type and range, output signal and approvals, then check the intrinsically safe entity values against the field device and cable. For temperature transmitters we confirm sensor type and wiring, 2, 3 or 4-wire RTD or thermocouple, the measuring range, HART revision and whether sensor redundancy is used, since the 5437 can switch to the secondary sensor when the primary fails. In SIL loops we refer to the safety manual, as the 9106 and 5437 are assessed for SIL 2/3 use, and confirm the proof test interval in the SIS documentation.

We supply genuine PR electronics temperature transmitters, I.S. interfaces, isolators, universal transmitters, 4500 series fronts and communication enablers, with traceable origin and the ATEX, IECEx and SIL documents the project requires. Units can be ordered preconfigured to the sensor type, range and tag listed on the instrument index, which shortens commissioning in large marshalling cabinets. When an older model is no longer produced, we say so at the start and propose the current version, comparing terminals, power rail connection and approvals. For plants with many loops we can prepare a spare list grouped by function, so that stock covers repeaters, temperature converters and switching amplifiers in balanced quantities. Calibration certificates for preconfigured transmitters can be included on request. PR electronics prices are given after the order codes and loop data are reviewed.

Rack and control modules
Rack and control modules · ISATIS editorial illustration

PR electronics product families we supply

  • 015437dual-input 2-wire HART 7 temperature transmitter
  • 023337loop-powered HART 7 temperature converter
  • 039106HART transparent repeater with SIL 2/3 assessment
  • 049113intrinsically safe temperature/mA converter
  • 054116universal transmitter with current, voltage and relay outputs
  • 064510 display/programming front and 4511/4512 communication enablers

Typical applications

  • 1Intrinsically safe isolation of HART transmitters in marshalling cabinets
  • 2Temperature measurement with redundant sensors on reactors and furnaces
  • 3Signal splitting and isolation between DCS and safety systems
  • 4Universal transmitters with alarm relays on utility skids

Buying guides for this equipment

FAQ

Common questions about PR electronics.

Can one 4510 front be used on several devices?

Yes. The 4510 display/programming front is detachable and can be moved between compatible PR devices to configure them or read their status, so one unit can serve a whole cabinet during commissioning.

Which barrier version of the 9106 should be chosen?

The two versions differ in barrier voltage and entity values. We compare both with the transmitter supply requirement, the loop resistance and the field device certificate before choosing the version for each loop.

What do you need to quote PR electronics devices?

The full order code with its letter suffix, the input type and range, the output signal, the hazardous-area classification and, for temperature loops, the sensor type and wiring. A loop drawing is helpful for I.S. interfaces.

Control, safety & networks

Other brands in this discipline.

All brands
  • ABB logo
  • Siemens logo
  • Honeywell logo
  • Yokogawa logo
  • Emerson logo
  • Allen-Bradley logo
  • Rockwell Automation logo
  • Schneider Electric logo
  • HIMA logo
  • ICS Triplex logo
  • Foxboro logo
  • Beckhoff logo
  • Mitsubishi logo
  • Omron logo
  • Fuji Electric logo
  • Yaskawa logo
  • Pepperl+Fuchs logo
  • Phoenix Contact logo
  • Weidmüller logo
  • Turck logo
  • Banner Engineering logo
  • Moore Industries logo
  • MOXA logo
  • Hirschmann (Belden) logo
  • Cisco logo
  • Advantech logo
  • Winsonic logo
  • Woodward logo
  • GE logo
  • Siemens Energy logo
  • Azbil logo
  • MTL logo
  • KEYENCE logo

Send us your datasheets, P&IDs or tender documents.

We review them and reply with a technical and commercial proposal.

info@iow.ir +98 21 2205 5712 Request a quote