ISATIS GROUP Arikeh Sanat IsatisInstrumentation · Control · Safety

Control, safety & networks

Turck equipment, sourced and integrated

Turck is a family-owned German automation group with headquarters in Mülheim an der Ruhr and production in Halver. For process plants it supplies excom remote I/O for hazardous areas, IMX12 isolating amplifiers, BL20 and BL67 I/O systems and inductive sensors.

Turck logo
Germany/Since 1965
Country
Germany
Founded
1965
Known for
Inductive sensors and fieldbus I/O

Related services

Related engineering guide

DCS or PLC? Choosing the Right Control System for Oil, Gas and Petrochemical Plants

Read the guide

Have a part number?

Send the part number or datasheet and we reply with availability, lead time and price.

Send an enquiry

Turck was founded in 1965 by the brothers Werner and Hans Turck, when they sold their first isolating switching amplifier; Hans Turck had run his own engineering office in Mülheim since 1960. The group rests on two companies: Hans Turck GmbH & Co. KG in Mülheim an der Ruhr for sales and marketing, and Werner Turck GmbH & Co. KG in Halver for development and manufacturing. It remains fully family-owned. The range for process industries includes the excom remote I/O system, whose field circuits are approved for Zones 0, 1, 20 and 21; IMX12 isolating amplifiers with ATEX and IECEx approvals and SIL 2 rating; the modular BL20 I/O in IP20 and BL67 in IP67; TBEN block I/O modules; Uprox inductive sensors; and RFID systems. Isolating switching amplifiers, the product the company began with, are still one of its core lines.

Turck devices are identified by a type code and a separate ident number, and both are needed for a reliable match. On an IMX12 isolator the type code shows function, channel count, output type and supply; IMX12-DI03-1S-2R-S/24VDC, for example, is a 1-channel digital input with relay outputs. So we check that the channel count, output contacts and power rail connection of the replacement are the same. For excom we read the gateway, power supply and module types, then check the module slots, the protocol of the host system and the Zone where the station is mounted, because a Zone 1 station needs the matching PSD24Ex power supply and housing. Entity parameters of intrinsically safe circuits are compared with the field device data, and SIL loops are checked against the safety manual of the device. For BL20 and BL67 we confirm the gateway protocol and base module type.

We supply genuine Turck isolating amplifiers, excom modules, gateways and power supplies, BL20 and BL67 electronic and base modules, TBEN block I/O, sensors and connection cables, with traceable origin and the ATEX, IECEx and SIL documents the project requires. If an older excom module or interface device is no longer listed, we tell the client at the start and propose the current version, noting any change in wiring, configuration file or gateway firmware. For marshalling cabinets with many isolators we can prepare a spare list grouped by loop type, so that stock covers analog inputs, digital inputs and valve outputs in sensible quantities. Delivery can be split so that loops needed for a planned shutdown arrive first. Turck prices are given after the type codes, ident numbers and site data are reviewed.

Rack and control modules
Rack and control modules · ISATIS editorial illustration

Turck product families we supply

  • 01excom remote I/O system for hazardous areas
  • 02IMX12 isolating amplifiers with ATEX, IECEx and SIL 2
  • 03BL20 modular I/O system in IP20
  • 04BL67 modular I/O system in IP67
  • 05TBEN block I/O modules for field mounting
  • 06Uprox inductive sensors
  • 07RFID read/write systems

Typical applications

  • 1Remote I/O stations in Zone 1 process areas
  • 2Intrinsically safe isolation of transmitters and switches in marshalling cabinets
  • 3Valve position feedback and solenoid valve control
  • 4Machine and skid I/O on compressors and loading systems

Buying guides for this equipment

FAQ

Common questions about Turck.

Can excom be installed in Zone 1?

Yes. Turck states that excom field circuits are approved for Zones 0, 1, 20 and 21, and the station can be mounted in Zone 1 with the appropriate power supply and housing. The approvals of each module are checked on the current certificate.

Why do you need both the type code and the ident number?

The type code describes the function, while the ident number identifies one exact variant. Two devices with similar codes can differ in supply, connector or approval, so both are used to avoid a wrong match.

What do you need to quote Turck parts?

The type code and ident number from the label, the host system protocol for remote I/O, and the hazardous-area classification of the installation. A photo of the module row or isolator rail is useful.

Control, safety & networks

Other brands in this discipline.

All brands
  • ABB logo
  • Siemens logo
  • Honeywell logo
  • Yokogawa logo
  • Emerson logo
  • Allen-Bradley logo
  • Rockwell Automation logo
  • Schneider Electric logo
  • HIMA logo
  • ICS Triplex logo
  • Foxboro logo
  • Beckhoff logo
  • Mitsubishi logo
  • Omron logo
  • Fuji Electric logo
  • Yaskawa logo
  • Pepperl+Fuchs logo
  • Phoenix Contact logo
  • Weidmüller logo
  • Banner Engineering logo
  • PR electronics logo
  • Moore Industries logo
  • MOXA logo
  • Hirschmann (Belden) logo
  • Cisco logo
  • Advantech logo
  • Winsonic logo
  • Woodward logo
  • GE logo
  • Siemens Energy logo
  • Azbil logo
  • MTL logo
  • KEYENCE logo

Send us your datasheets, P&IDs or tender documents.

We review them and reply with a technical and commercial proposal.

info@iow.ir +98 21 2205 5712 Request a quote