ISATIS GROUP Arikeh Sanat IsatisInstrumentation · Control · Safety

Control, safety & networks

ICS Triplex equipment, sourced and integrated

ICS Triplex is the safety system brand of Rockwell Automation, with its base in Maldon, Essex, in the United Kingdom. Its Trusted and AADvance controllers run emergency shutdown, fire and gas and burner management functions in oil, gas and petrochemical plants.

ICS Triplex logo
United Kingdom
Country
United Kingdom
Part of
Rockwell Automation
Known for
TMR safety and ESD systems

Related services

Related engineering guide

Safety Instrumented Systems and SIL: A Practical Guide to IEC 61511

Read the guide

Have a part number?

Send the part number or datasheet and we reply with availability, lead time and price.

Send an enquiry

ICS Triplex, the trading name of Industrial Control Services Group, built its name on triple modular redundant (TMR) safety controllers, and Rockwell Automation acquired the company in 2007. Three product generations are found in plants today. Trusted is a TMR system in which each processor and I/O module contains three independent channels that vote on every result, and it suits cabinets with a high number of SIL 3 loops. AADvance is a newer modular controller that can be built in simplex, dual or triple configuration, so the level of redundancy matches each safety function. Regent is an older line that is no longer produced, and its installed systems are usually upgraded to Trusted.

Safety systems are changed under the plant's functional safety management, so we work from the safety requirements specification and the existing configuration. Before supplying a module we check its part number, hardware revision and firmware against the system release and the Trusted Toolset or AADvance Workbench version in use, because a mismatch can stop a module from joining the system. For upgrades from Regent or older Trusted releases we review the application logic, I/O count and communication links to the DCS, plan the cutover around a shutdown and proof test each safety function after the change.

We supply genuine ICS Triplex processor, I/O, communication and power modules, chassis and field termination assemblies with traceable origin and the documentation a safety audit asks for. Because many of these systems are 15 or 20 years old, we help plants build a spares list from the installed modules and from the items that are no longer produced, so a failed card does not leave a safety function in bypass. ICS Triplex prices are given after the module list and revisions are checked.

Rack and control modules
Rack and control modules · ISATIS editorial illustration

ICS Triplex product families we supply

  • 01TrustedTMR safety instrumented system
  • 02Trusted processor, I/O and communication modules
  • 03AADvancesafety controller in simplex, dual or TMR configuration
  • 04Regentlegacy safety system spares and upgrade
  • 05Trusted Toolset and AADvance Workbenchengineering software
  • 06Field termination assemblies, chassis and power supplies

Typical applications

  • 1Emergency shutdown (ESD) systems
  • 2Fire and gas detection logic
  • 3Burner management and compressor protection
  • 4Spares and migration of legacy Regent and Trusted systems

FAQ

Common questions about ICS Triplex.

What does TMR mean in a Trusted system?

Triple modular redundancy: each processor and I/O module has three independent channels that process the same signal and vote two out of three. A single fault is detected and outvoted, so the safety function keeps working while the faulty module is replaced online.

Can a Regent system be upgraded without rewiring the field?

In many cases the field cabling is kept and only the controller and I/O change, but this depends on the termination hardware and the I/O count. We review the existing panels and logic first and then propose the upgrade path.

What do you need to supply a spare module for an ICS Triplex system?

The full part number and revision from the module label, the system type and, if possible, the software release in use. With these we confirm compatibility and tell you whether the module is current or no longer produced.

Control, safety & networks

Other brands in this discipline.

All brands
  • ABB logo
  • Siemens logo
  • Honeywell logo
  • Yokogawa logo
  • Emerson logo
  • Allen-Bradley logo
  • Rockwell Automation logo
  • Schneider Electric logo
  • HIMA logo
  • Foxboro logo
  • Beckhoff logo
  • Mitsubishi logo
  • Omron logo
  • Fuji Electric logo
  • Yaskawa logo
  • Pepperl+Fuchs logo
  • Phoenix Contact logo
  • Weidmüller logo
  • Turck logo
  • Banner Engineering logo
  • PR electronics logo
  • Moore Industries logo
  • MOXA logo
  • Hirschmann (Belden) logo
  • Cisco logo
  • Advantech logo
  • Winsonic logo
  • Woodward logo
  • GE logo
  • Siemens Energy logo
  • Azbil logo
  • MTL logo
  • KEYENCE logo

Send us your datasheets, P&IDs or tender documents.

We review them and reply with a technical and commercial proposal.

info@iow.ir +98 21 2205 5712 Request a quote