ISATIS GROUP Arikeh Sanat IsatisInstrumentation · Control · Safety

Field instruments & metering

Mettler Toledo equipment, sourced and integrated

Mettler Toledo is a precision instrument maker with its corporate headquarters in Greifensee, Switzerland, and executive offices in Columbus, Ohio. In process plants its equipment weighs tanks, silos and vehicles and measures pH and dissolved oxygen in process lines.

Mettler Toledo logo
Switzerland/Since 1945
Country
Switzerland
Founded
1945
Known for
Industrial weighing and pH sensors

Related services

Related engineering guide

Analyzer Sampling System Design: 7 Principles for Reliable Measurement

Read the guide

Have a part number?

Send the part number or datasheet and we reply with availability, lead time and price.

Send an enquiry

Erhard Mettler set up a precision mechanics business near Zurich in 1945 and built it on a single-pan balance that could be produced in series. The chemical group Ciba-Geigy took control of Mettler in 1980 and in 1989 added the American Toledo Scale business, whose roots go back to the Toledo Computing Scale company of 1901, and the combined business went on to operate as Mettler Toledo. The company was floated on the New York Stock Exchange in 1997, where it trades as MTD, and it is not owned by another group. For industry the range covers weighing terminals such as the IND570 and its hazardous-area variant IND570xx, POWERCELL digital load cells and PowerMount weigh modules for tanks and silos. The process analytics division makes InPro sensors for pH, ORP and dissolved oxygen, the M400 transmitters, and the ISM digital sensor platform, which keeps calibration data and diagnostics inside the sensor head.

Weighing and analytical spares are chosen from different data, so we treat them separately. For a weighing system we start from the terminal model and the load cell type on each cell label. An IND570 working with POWERCELL load cells communicates digitally with every cell, and the version decides how many cells it can serve: up to 14 on the IND570 and up to six on the IND570xx. Capacity, accuracy class, mounting hardware and cable length are matched for each cell, and for vessels we check the PowerMount module against the support design, thermal expansion and external loads. In hazardous areas the IND570xx, its power supply and its approvals are compared with the zone. For pH and oxygen measurement we read the full sensor code, which fixes the electrode type, shaft length, temperature sensor and connector, and confirm whether the loop uses ISM or analog sensors, because an ISM sensor needs a matching transmitter input and must fit the existing housing.

We supply genuine Mettler Toledo weighing terminals, POWERCELL load cells, PowerMount weigh modules, junction boxes, InPro sensors, M400 transmitters and the cables and accessories that go with them, with traceable origin and the conformity, hazardous-area and material certificates the project calls for. ISM sensors carry their calibration data in the sensor, so they can be checked in iSense software away from the process and installed without a new calibration. For weighing systems we can arrange the calibration documents needed after a load cell change. When a terminal or sensor has been superseded, we say so at the start and propose the current model with notes on interfaces, mounting and any change in cell count or communication. pH electrodes have a limited service life, so for plants with many measuring points we can plan rotating stocks by electrode type. Mettler Toledo prices are given after the model codes and process data are reviewed.

Sensor and analytical transmitter
Sensor and analytical transmitter · ISATIS editorial illustration

Mettler Toledo product families we supply

  • 01IND570weighing terminal for process weighing and filling control
  • 02IND570xxweighing terminal for Division 2 and Zone 2/22 areas
  • 03POWERCELLdigital load cells with individual cell diagnostics
  • 04PowerMountweigh modules for tank and silo weighing
  • 05InPro 4260ipH and ORP sensor with ISM diagnostics
  • 06InPro 6850idissolved oxygen sensor with ISM
  • 07M400transmitters for process analytics sensors

Typical applications

  • 1Tank and silo weighing for inventory and batching
  • 2Truck scales at loading terminals
  • 3pH control in water treatment and chemical dosing
  • 4Dissolved oxygen measurement in water and effluent systems

Buying guides for this equipment

FAQ

Common questions about Mettler Toledo.

How many POWERCELL load cells can an IND570 terminal serve?

According to Mettler Toledo, the IND570 supports a network of up to 14 POWERCELL load cells and the IND570xx up to six. We check the terminal version and the cell count of the scale before proposing a replacement.

What is ISM in Mettler Toledo sensors?

ISM is Mettler Toledo's digital sensor technology. The sensor stores its calibration data and diagnostics, such as remaining lifetime and time to the next calibration, so it can be calibrated away from the process and swapped in without recalibration.

What do you need to quote Mettler Toledo equipment?

For weighing, the terminal model and the label data of each load cell or weigh module. For analytics, the full sensor or transmitter code, the measured parameter, process temperature and pressure, and whether the loop uses ISM or analog sensors.

Field instruments & metering

Other brands in this discipline.

All brands
  • Endress+Hauser (E & H) logo
  • Rosemount logo
  • KROHNE logo
  • VEGA logo
  • WIKA logo
  • JUMO logo
  • SICK logo
  • Elster logo
  • pFlow logo
  • Daniel logo
  • Micro Motion logo
  • Magnetrol logo
  • Brooks Instrument logo
  • Sierra Instruments logo
  • Badger Meter logo
  • KOBOLD logo
  • Ashcroft logo
  • Barksdale logo
  • United Electric controls logo
  • Dwyer Instruments logo
  • Panametrics logo
  • Vaisala logo
  • Raytek logo
  • Jaquet logo
  • BETA logo
  • ifm logo
  • Balluff logo

Send us your datasheets, P&IDs or tender documents.

We review them and reply with a technical and commercial proposal.