Field instruments & metering
Brooks Instrument equipment, sourced and integrated
Brooks Instrument is an American maker of flow, pressure and vacuum instruments based in Hatfield, Pennsylvania, and a division of ITW. It is best known for thermal mass flow controllers and for glass and metal tube variable area flowmeters used on gas and liquid lines.
- Country
- United States
- Founded
- 1946
- Part of
- ITW
- Known for
- Mass flow controllers and rotameters
Related services
Have a part number?
Send the part number or datasheet and we reply with availability, lead time and price.
Send an enquiryStephen A. Brooks founded the company in 1946 in Lansdale, Pennsylvania, and its early products were variable area flowmeters. Brooks later became one of the main names in thermal mass flow control, and Illinois Tool Works acquired it in January 2012. Two groups of products appear in most plants and laboratories. Thermal mass flow controllers and meters, such as the SLA Series for analog and digital process work and the GF Series used widely on semiconductor tools, meter and control gas flow directly in mass units. Variable area meters give a local reading without power: Sho-Rate and GT1600 glass tube meters on purge, sample and utility lines, and MT3809 and MT3750 metal tube meters where pressure, temperature or opaque fluids rule out glass. The Quantim Coriolis controller covers low-flow liquid and gas dosing.
A mass flow controller is calibrated for a gas, a range and a set of process conditions, so we start from those rather than from the model alone. We record the gas or gas mixture, full scale flow, inlet and outlet pressure, the seal material and the signal or protocol the controller uses (analog 0-5 V or 4-20 mA, or a digital link such as DeviceNet, PROFIBUS or EtherCAT), and we check that the valve orifice suits the pressure drop. For variable area meters we confirm the float and tube combination for the fluid density and viscosity, the scale units, the connection and any alarm or transmitter option. After installation we check zero and a reference point against a known flow where the site can provide one.
Brooks instruments are identified by a full model code that fixes the gas, range, seals, connections and electronics, so we quote against the code on the label or the original data sheet. We supply genuine Brooks mass flow controllers and meters, variable area meters, spare tubes, floats and electronics with traceable origin and the calibration certificate for each unit. When a legacy controller is no longer produced, we propose the current equivalent with matching fittings and signal so it fits the gas panel with minimal change. Brooks prices are given after the gas data and model codes are confirmed.
Brooks Instrument product families we supply
- 01SLA Seriesthermal mass flow controllers and meters for process use
- 02GF Seriesthermal mass flow controllers for semiconductor and high purity gas
- 03QuantimCoriolis mass flow controllers for low flow liquids and gases
- 04MT3809 and MT3750metal tube variable area flowmeters
- 05Sho-Rate and GT1600glass tube variable area flowmeters
Typical applications
- 1Gas blending and dosing in pilot plants and laboratories
- 2Purge, sample and seal gas flow indication
- 3Carrier and calibration gas control on analyzer systems
- 4Flow monitoring on chemical injection and utility lines
Buying guides for this equipment
FAQ
Common questions about Brooks Instrument.
Can one Brooks mass flow controller be used for a different gas?
A thermal controller is calibrated for a specific gas, and using it on another gas changes the reading. Some Brooks digital controllers can hold several gas and range calibrations, but each one has to be set up and verified. Tell us the gases and ranges and we confirm what is possible.
When is a metal tube variable area meter needed instead of glass?
Glass tube meters suit clean fluids at low pressure where a direct view is useful. A metal tube meter such as the MT3809 is used for higher pressure and temperature, opaque or hazardous fluids, and where an electrical output or alarm is required.
What do you need to source a Brooks replacement?
The full model code and serial number from the label, plus the gas, range and pressure conditions. With these we confirm whether the same model is still available or which current model fits the existing connections and signal.
Field instruments & metering
Other brands in this discipline.
Send us your datasheets, P&IDs or tender documents.
We review them and reply with a technical and commercial proposal.
info@iow.ir +98 21 2205 5712 Request a quote







