Field instruments & metering
Raytek equipment, sourced and integrated
Raytek is an American brand of non-contact infrared temperature measurement from Santa Cruz, California, now part of Fluke Process Instruments. Its fixed pyrometers and thermal imagers measure surfaces that are moving, very hot or out of reach, from kiln shells to heater tubes.
- Country
- United States
- Founded
- 1963
- Part of
- Fluke Process Instruments
- Known for
- Infrared pyrometers and thermal scanners
Related services
Have a part number?
Send the part number or datasheet and we reply with availability, lead time and price.
Send an enquiryHerb Berman founded Raytek in 1963. In 2002 the company was bought by Fluke Corporation. Ircon, another infrared specialist, joined Raytek in 2007, and in 2015 Fluke combined the Raytek, Ircon and Datapaq product lines under the name Fluke Process Instruments, keeping Raytek as a product brand. The range covers compact sensors such as the MI3, a stainless steel miniature pyrometer with IP65 protection and a range of -40 to 1800 °C, and the CI and CM series; the Marathon MM family of high-performance sensors; and the Endurance series of single-colour and two-colour ratio pyrometers measuring from 50 to 3200 °C. The Thermalert 4.0, introduced in 2018, covers -40 to 2250 °C, has models with ATEX, IECEx and CCC intrinsic safety approvals and was designed to replace older Raytek TX and XR heads. ThermoView TV40 thermal imagers handle area monitoring.
Selecting an infrared pyrometer starts with the target, not the catalogue. For a replacement we read the model code on the sensor head, which fixes the spectral response, temperature range, optical resolution and output, and check it against the target: its material and emissivity, its size at the working distance, and what lies between the sensor and the surface. Metals with low or changing emissivity, or targets seen through steam, dust or a sight glass, often need a short-wavelength or two-colour ratio sensor such as an Endurance model rather than a general-purpose head. The distance-to-spot ratio is compared with the real mounting distance so that the spot stays inside the target. Ambient temperature at the head decides whether a water-cooled or air-purged housing is needed, and in hazardous areas we confirm the intrinsically safe version and its barrier. The analog or fieldbus output is matched with the control system, and fixture adapters are chosen when a Thermalert 4.0 replaces a Marathon MM or Modline head.
We supply genuine Raytek and Fluke Process Instruments sensors, electronics boxes, cables, air purge collars, water-cooled housings, mounting fixtures, protective windows and thermal imagers, with traceable origin and the calibration and hazardous-area certificates supplied with each instrument. Infrared sensors drift slowly and their windows get dirty, so for critical points we can arrange periodic checks against a reference source or supply exchange heads. Many plants still run Raytek models that are no longer produced, such as the Raynger 3i or older Thermalert heads; we say so at the start and propose the current model with a check of optics, output, cable and mounting, so the measurement is not lost during the change. Spare heads for kiln or furnace lines can be prepared with the settings of the installed units. Raytek prices are given after the model codes and target data are reviewed.
Raytek product families we supply
- 01MI3miniature pyrometers with separate electronics, -40 to 1800 °C
- 02CI and CMcompact infrared temperature sensors
- 03Marathon MMhigh-performance infrared sensors in five models
- 04Endurancesingle-colour and two-colour ratio pyrometers up to 3200 °C
- 05Thermalert 4.0spot pyrometers from -40 to 2250 °C with intrinsically safe models
- 06ThermoView TV40industrial thermal imagers with an integrated visible-light camera
- 07Air purge collars, water-cooled housings and mounting fixtures
Typical applications
- 1Fired heater and furnace tube temperature monitoring
- 2Shell temperature of rotary kilns and dryers
- 3Non-contact temperature measurement in hazardous areas
- 4Replacement of discontinued pyrometer heads
Buying guides for this equipment
FAQ
Common questions about Raytek.
Why does an infrared pyrometer read differently from a thermocouple?
An infrared sensor measures emitted radiation, so its reading depends on the emissivity setting and on anything between the sensor and the target. We check emissivity, wavelength and spot size against the target before treating a difference as a sensor fault.
Can a Thermalert 4.0 replace an older Raytek or Ircon head?
Fluke designed the Thermalert 4.0 as an upgrade for Raytek TX, XR and Marathon and Ircon Modline 4 and 7 installations, with adapters for Marathon MM and Modline 4 fixtures. We still check range, wavelength and output before proposing it.
Is Raytek still a separate company?
No. Raytek has been part of Fluke since 2002, and since 2015 its products have been sold under Fluke Process Instruments together with the Ircon and Datapaq lines.
Field instruments & metering
Other brands in this discipline.
Send us your datasheets, P&IDs or tender documents.
We review them and reply with a technical and commercial proposal.
info@iow.ir +98 21 2205 5712 Request a quote







