Compare mass flow controller ranges quoted at 0 °C and 20 °C. Keep the gas, reference pressure and temperature alongside the stated standard volumetric flow.
State the gas and the reference temperature and pressure behind any standard volumetric unit. Identical numerical ranges with different definitions of standard conditions can correspond to different amounts of gas.
Specify the gas and the valve conditions
Is the gas pure or a mixture? What is the composition range? What differential pressure is available across the control valve? A device calibrated for a different gas requires a model-specific assessment of suitability and error.
Two meanings of standard volume
Suppose one sheet uses 0 °C and another uses 20 °C at the same reference pressure. Even for an ideal gas, the volume of a fixed amount changes with absolute temperature. Request both offers on the same reference basis.
Enquiry checklist
| Item | What to record |
|---|---|
| Range basis | Gas identity and reference conditions. |
| Process | Inlet and outlet pressures across the required operating loads. |
| Control | Command and feedback signal types. |
Check the quotation Copy a complete indication from the old scale or configuration screen, including its unit. Use that example to ask how the same flow would be represented on the proposed unit.
As a cross-check, the same amount of ideal gas occupies about 1.073 times as much volume at 20 °C as at 0 °C at the same reference pressure. Keep both temperature and pressure beside the converted figure on the comparison sheet.
Include normal operating flow as well as the maximum. If the process usually runs near the bottom of the range, the performance there is relevant to the buying decision.
Sample enquiry to ISATIS
Please quote a controller for the stated mixture and reference conditions. Normal flow and upstream and downstream pressures are attached. Confirm the calibration units and command input.