Ordering a pressure gauge? Match the thread designation, sealing face and bottom or back connection so the dial remains visible after installation.
A request for a half-inch pressure gauge leaves several interfaces undefined. The thread designation, sealing face and direction of the connection determine whether the gauge fits the existing installation.
Read the mating connection drawing
Copy the full designation, including letters such as G or NPT. Record whether each side is male or female. A visual match or a few turns of engagement does not establish compatibility. Allow room for the wrench and for the operator to see the dial once the instrument is in position.
Two gauges with the same 100 mm dial
Both offers have the right range and dial diameter. One gauge connects at the bottom and the other at the back. Even with the correct thread, the second changes the viewing direction and clearance in the panel. A side photograph makes the difference visible before purchase.
Enquiry checklist
| Item | What to record |
|---|---|
| Thread reference | Quote the complete designation from a drawing or identified part. |
| Installation view | Include front and side photographs showing the intended reading position. |
| Supply boundary | List any required adaptor or sealing washer separately. |
Check the quotation On the quotation drawing, mark the connection on each side and identify which seals or adapters come with the assembly. This makes two offers with the same instrument range comparable.
If the thread has not been identified, mark it as open and send the mating connection drawing. Do not convert an assumption into a purchase specification.
Sample enquiry to ISATIS
Please quote a replacement gauge for the attached mating connection. Confirm the thread form, sealing arrangement, connection position and any adaptor needed.