ISATIS GROUP Arikeh Sanat IsatisInstrumentation · Control · Safety

Electrical, power & Ex

Pfannenberg equipment, sourced and integrated

Pfannenberg is a Hamburg-based German manufacturer of thermal management for electrical enclosures, liquid cooling (chillers) and visual and audible signalling devices for industrial plants.

Pfannenberg logo
Germany/Since 1954
Country
Germany
Founded
1954
Known for
Signal beacons and enclosure cooling

Related services

Related engineering guide

How to Read an Instrument Order Code Before Requesting a Spare

Read the guide

Have a part number?

Send the part number or datasheet and we reply with availability, lead time and price.

Send an enquiry

Pfannenberg was founded in Hamburg in 1954 by the electrical engineer Otto Pfannenberg, who kept running into control cabinets where components failed from heat. The answer was the Filterfan, introduced in 1958, followed in 1962 by an industrial flashing light, and these two ideas still define the company's two main fields. Today the group works in three areas: enclosure thermal management (Filterfans such as the PTF top-mounted units, DTS and DTI cooling units including the Green Series and compact 6201C and 6301C models, DTFS units and Slim Series air/water heat exchangers), liquid cooling with chillers such as CPC, PC, CCE, EB 2.0 and PWW 2.0, and signalling with the PATROL, PYRA and QUADRO families, BR 50 signal towers and Pfire devices for EN 54 fire alarm systems. The headquarters remain in Hamburg, with operations in the USA, Italy, Singapore, China and Brazil.

Selecting enclosure cooling starts with a heat balance: the power dissipated by drives, power supplies and PLCs inside the cabinet, the surface area of the enclosure, the maximum ambient temperature and the target internal temperature. If ambient air is always cooler than the target, a Filterfan with the right air flow and filter class is enough; if not, a cooling unit or an air/water heat exchanger is needed. For a replacement we match the full part number on the rating label, since one model family covers several capacities, voltages (for example 230 V or 400 V, 50/60 Hz), mounting types (side, top or recessed) and controller options. Dusty sites such as cement and steel plants also need the correct filter mat and a check of condensate drainage. For signalling devices the label gives the colour, flash or steady mode, supply voltage and, for sounders, the tone set and sound level. For hazardous areas, Pfannenberg lists Ex-rated signalling for Zone 2 and Zone 22, such as QUADRO LED-RGB-3G/3D, and the marking on the device must match the zone classification of the site.

We supply complete units and the parts that wear in service: filter mats and replacement filters, fans, controllers, condensate evaporation accessories, lenses and mounting brackets for beacons. For chillers we confirm the cooling capacity, refrigerant, pump and hydraulic connections, and the fluid type before any replacement or upgrade. Where a model has been superseded, we report the current equivalent and any change in cut-out dimensions or electrical connection before ordering, so that the new unit fits the existing cabinet opening. Quotations are prepared after the rating label photo, the cabinet heat load data and the site conditions have been reviewed.

Electrical enclosures and cable entries
Electrical enclosures and cable entries · ISATIS editorial illustration

Pfannenberg product families we supply

  • 01Filterfans, including PTF top filter fans
  • 02DTS and DTI cooling units, Green Series and compact models
  • 03Slim Series air/water heat exchangers
  • 04ChillersCPC, PC, CCE, EB 2.0 and PWW 2.0
  • 05PATROL and PYRA beacons and sounders
  • 06QUADRO LED signalling, including Ex Zone 2 and 22 versions
  • 07BR 50 signal towers and Pfire EN 54 fire alarm devices

Typical applications

  • 1Cooling of drive and MCC cabinets in hot, dusty plants
  • 2Control room and field panels in oil, gas and petrochemical sites
  • 3Process and machine cooling with industrial chillers
  • 4Alarm and status signalling on cranes, conveyors and process units

Buying guides for this equipment

FAQ

Common questions about Pfannenberg.

How do I choose between a Filterfan and a cooling unit?

A Filterfan works only when the ambient air is cooler than the required cabinet temperature. If ambient air can be hotter, or the air is heavily contaminated, a closed loop cooling unit or an air/water heat exchanger is the correct choice.

Can Pfannenberg signalling be used in hazardous areas?

Pfannenberg offers Ex-rated signalling devices, for example QUADRO LED-RGB-3G/3D for Zone 2 and Zone 22. The Ex marking on the device label must cover the zone, gas group and temperature class of the installation.

What do you need to quote a Pfannenberg replacement?

A photo of the rating label with the full part number, the supply voltage and frequency, the mounting type and, for cooling units, the cabinet heat load and maximum ambient temperature.

Electrical, power & Ex

Other brands in this discipline.

All brands
  • APC logo
  • Eaton logo
  • Lovato Electric logo
  • Mean Well logo
  • ComAp logo
  • Cortem logo
  • BARTEC logo
  • R. STAHL logo
  • MEDC logo
  • Hawke International logo
  • Itelcond logo
  • Rittal logo
  • WAGO logo

Send us your datasheets, P&IDs or tender documents.

We review them and reply with a technical and commercial proposal.

info@iow.ir +98 21 2205 5712 Request a quote