ISATIS GROUP Arikeh Sanat IsatisInstrumentation · Control · Safety

Electrical, power & Ex

Hawke International equipment, sourced and integrated

Hawke International is a British manufacturer of cable glands and termination products for hazardous and industrial areas, based in Ashton-under-Lyne near Manchester. It has been part of the US group Hubbell Incorporated since 2002.

Hawke International logo
United Kingdom
Country
United Kingdom
Part of
Hubbell Incorporated
Known for
Ex cable glands

Related services

Related engineering guide

Hazardous Area Classification and Ex Equipment: Zones, Gas Groups and Protection Concepts

Read the guide

Have a part number?

Send the part number or datasheet and we reply with availability, lead time and price.

Send an enquiry

Hawke makes brass and other metal cable glands and cable connectors at Ashton-under-Lyne, near Manchester, England, and traces its cable gland production back to the 1950s. Hubbell Incorporated acquired the shares of Hawke Cable Glands Limited in March 2002 in a cash transaction and placed it in its Electrical segment; at the time Hubbell described Hawke as a leader in brass cable glands and cable connectors for watertight terminations on fixed and floating offshore production platforms and drill ships. Today the brand trades as Hawke International, a member of the Hubbell group. Its best known products are the 501/453/UNIV gland for armoured and braided cables, the ICG 653/UNIV compound barrier gland and the 501/421 gland for unarmoured cables, used on Ex d, Ex e and dust protected equipment.

Gland selection starts with the cable, not the equipment. We need the cable type and armour (single wire armour W, wire braid X, steel tape Z or unarmoured elastomer and plastic cables), the inner sheath and outer sheath diameters and the armour wire size, then the entry thread and size on the equipment, such as M20, M25 or NPT. The 501/453/UNIV is certified for flameproof, increased safety, dust protection and restricted breathing applications and seals on both inner and outer sheaths. Where the cable entry into an Ex d enclosure needs a barrier seal, for example because of the enclosure volume, gas group or a cable that is not substantially compact, the ICG 653/UNIV barrier gland with its inspectable and repairable compound seal is chosen, and a barrier upgrade kit turns a 501/453/UNIV into an ICG 653/UNIV. The 501/421 is a compression gland for unarmoured cables and is not used on armoured runs. Hawke part codes carry the gland type, size letter and thread, for example 453UBM25 for a 501/453/UNIV size B with M25 entry.

We supply Hawke cable glands with matching shrouds, earth tags, locknuts and sealing washers for new installations and for maintenance on refineries, gas plants, offshore platforms and process skids. Requests start from the cable schedule, which gives cable type and diameters, and the equipment entry list, so each gland is sized for its cable and not only for its thread. Where the existing gland code is known, we check it against the cable before reordering, because cable changes during a project often leave glands out of range. Certificate copies with the Ex marking are provided with the delivery for the inspection records.

Electrical enclosures and cable entries
Electrical enclosures and cable entries · ISATIS editorial illustration

Hawke International product families we supply

  • 01501/453/UNIV glands for armoured and braided cables
  • 02ICG 653/UNIV compound barrier glands
  • 03Barrier upgrade kits for 501/453/UNIV
  • 04501/421 glands for unarmoured cables
  • 05Cable connectors for watertight terminations
  • 06Shrouds, earth tags, locknuts and sealing washers

Typical applications

  • 1Cable entries into Ex d and Ex e equipment in Zone 1 and Zone 2
  • 2Offshore platforms and drill ships
  • 3Motor and instrument terminations in refineries and gas plants
  • 4Dust hazardous areas in grain and powder handling

Buying guides for this equipment

FAQ

Common questions about Hawke International.

When do I need a barrier gland like ICG 653/UNIV?

When the entry standard for the Ex d enclosure requires a barrier seal, which depends on the enclosure volume, the gas group and the cable construction. The compound barrier stops gas from passing through the cable core into the enclosure.

Can 501/421 be used on armoured cable?

No. The 501/421 seals only on the outer sheath of unarmoured cables. For armoured or braided cables use the 501/453/UNIV or the ICG 653/UNIV.

What do you need to quote Hawke glands?

The cable type and armour, inner and outer sheath diameters, the entry thread and size, and the Ex protection concept of the equipment. If you have the old part code, such as 453UBM25, send it with the cable data.

Electrical, power & Ex

Other brands in this discipline.

All brands
  • APC logo
  • Eaton logo
  • Lovato Electric logo
  • Mean Well logo
  • ComAp logo
  • Cortem logo
  • BARTEC logo
  • R. STAHL logo
  • MEDC logo
  • Pfannenberg logo
  • Itelcond logo
  • Rittal logo
  • WAGO logo

Send us your datasheets, P&IDs or tender documents.

We review them and reply with a technical and commercial proposal.

info@iow.ir +98 21 2205 5712 Request a quote