ISATIS GROUP Arikeh Sanat IsatisInstrumentation · Control · Safety

Test & calibration

Isotech equipment, sourced and integrated

Isotech is the trading name of Isothermal Technology Limited of Southport, England, a maker of temperature calibration equipment from primary standards for national laboratories to portable dry blocks for site work.

Isotech logo
United Kingdom/Since 1980
Country
United Kingdom
Founded
1980
Known for
Dry-block and fixed-point temperature calibrators

Related services

Related engineering guide

Temperature Measurement: RTD or Thermocouple, Thermowells and Transmitters

Read the guide

Have a part number?

Send the part number or datasheet and we reply with availability, lead time and price.

Send an enquiry

Isotech was started in 1980 by John Tavener from a small purpose-built laboratory in Southport, Merseyside, where Isothermal Technology Limited is still based at Pine Grove. In 1996 the manufacturing technology of the Jarrett water triple point cells, produced since 1958, passed to Isotech, and the cells are now sold as Isotech-Jarrett cells. The range covers ITS-90 fixed point cells from argon to copper, including slim cells, along with fixed point furnaces and blackbody sources, precision thermometry bridges such as the milliK and the microK, which Isotech states can reach uncertainties as low as 7.5 μK, and industrial calibrators. The industrial range includes the Fast-Cal and Quick-Cal portable dry blocks, the Jupiter series for fast calibration to 660 °C with 35 mm removable inserts, and larger units such as Hyperion, Drago, Medusa, Pegasus, Gemini, Europa and Venus.

The choice between these instruments depends on the uncertainty the user's quality system requires. For field checks of process temperature sensors, a dry block such as Fast-Cal or Jupiter, with an insert drilled for the probe diameters on site, gives fast results; the uncertainty depends on stability, radial and axial uniformity, immersion depth and whether an external reference thermometer is used. For short or odd-shaped sensors a stirred liquid bath gives better uniformity. A calibration laboratory that needs lower uncertainty uses a standard platinum resistance thermometer with a bridge such as the milliK, which also reads thermistors, thermocouples and 4 to 20 mA signals over a range of -270 °C to 1820 °C, and checks the reference at fixed points such as the water triple point. Isotech also offers UKAS calibration certificates for its instruments, which gives traceability to national standards.

We match each Isotech order to the model, temperature range, supply voltage and insert or bath configuration. Inserts with the right bore sizes, reference probes, thermocouple and PRT sensors, fixed point cell maintenance accessories, carrying cases and software are supplied to the same model code. When a laboratory is planning a fixed point or primary setup, we review the temperatures needed, the existing reference thermometers and the uncertainty budget before proposing cells, furnaces or bridges. Quotations follow this review and the certificate requirements of the user.

Measuring instrument on a laboratory bench
Measuring instrument on a laboratory bench · ISATIS editorial illustration

Isotech product families we supply

  • 01Fast-Cal and Quick-Cal portable dry block calibrators
  • 02Jupiter dry blocks to 660 °C with 35 mm inserts
  • 03Hyperion, Drago and other large volume calibrators and baths
  • 04milliK precision thermometer and microK bridge
  • 05ITS-90 fixed point cells from argon to copper, including slim cells
  • 06Isotech-Jarrett water triple point cells
  • 07Blackbody sources and fixed point furnaces

Typical applications

  • 1Site calibration of thermocouples, RTDs and temperature transmitters
  • 2Temperature calibration laboratories in industry and utilities
  • 3Pharmaceutical temperature mapping and validation equipment checks
  • 4Primary and national standards temperature laboratories

Buying guides for this equipment

FAQ

Common questions about Isotech.

What is the difference between a dry block and a fixed point cell?

A dry block produces an adjustable temperature for comparison calibration against a reference sensor. A fixed point cell realises a defined ITS-90 temperature, such as the water triple point, and is used to calibrate reference thermometers at the lowest uncertainty.

Are Isotech calibrators supplied with traceable certificates?

Isotech offers UKAS calibration certificates for its instruments. The certificate type and the calibration points should be agreed at the time of order.

What do you need to quote Isotech equipment?

The temperature range, the types and diameters of the sensors to be calibrated, the required uncertainty, the supply voltage and the certificate type. For laboratories, the list of existing reference thermometers is also useful.

Test & calibration

Other brands in this discipline.

All brands
  • Fluke logo
  • Beamex logo
  • Druck logo
  • Additel logo
  • Martel Electronics logo
  • Elcometer logo
  • Dakota NDT logo
  • Megger logo
  • Testo logo
  • Hioki logo
  • Chauvin Arnoux logo
  • Keysight logo
  • Tektronix logo
  • FLIR logo

Send us your datasheets, P&IDs or tender documents.

We review them and reply with a technical and commercial proposal.

info@iow.ir +98 21 2205 5712 Request a quote