ISATIS GROUP Arikeh Sanat IsatisInstrumentation · Control · Safety

Test & calibration

Additel equipment, sourced and integrated

Additel Corporation is a US manufacturer of process calibration tools headquartered in Brea, California. It makes pressure calibrators and controllers, pressure gauges and modules, test pumps, dry well calibrators and multifunction process calibrators.

Additel logo
United States
Country
United States
Known for
Pressure and temperature calibrators

Related services

Related engineering guide

Industrial Instrument Calibration: Why, When and How

Read the guide

Have a part number?

Send the part number or datasheet and we reply with availability, lead time and price.

Send an enquiry

Additel is based at Brea, California, where it runs its assembly and manufacturing area, its repair service and an ISO/IEC 17025 calibration laboratory accredited by NVLAP under lab code 600214-0. The company also lists offices in Pleasant Grove, Utah, and in Odense, Denmark, for European customers. Its catalogue covers pressure controllers, industrial pressure sensors, handheld and automated pressure calibrators such as the ADT760 and ADT762 series, digital pressure gauges, pressure modules and readouts, hand and electric test pumps, temperature calibrators and baths including reference dry wells such as the 878 series, temperature probes and readouts, multifunction process calibrators and calibration software.

Choosing a calibrator begins with the instruments it has to check. For pressure, the range must cover the transmitters and gauges under test while keeping the stated accuracy at the points used most often, and the pressure type (gauge, absolute or differential) and medium (gas or hydraulic) decide between a handheld automatic calibrator, a bench controller or a pump with a reference gauge. A useful rule is that the reference should be several times more accurate than the device under test. For temperature, the dry well range, stability, axial uniformity and insert bore sizes must fit the probes and thermowell sensors on site, and a separate reference probe improves the uncertainty compared with the internal control sensor. Accuracy figures in Additel datasheets are stated as a percentage of reading or of full scale over a stated period, so the calibration interval should follow the specification used.

Every calibrator we supply is checked against its model code and options: pressure range, number of internal sensors, external module ports, electrical measurement functions, communication (for example HART) and the documentation package. We can supply the instrument with a calibration certificate traceable to national standards, and arrange recalibration at the end of the interval. Spare parts and accessories such as pressure modules, test hoses and adapters, dry well inserts, reference probes, batteries and carrying cases are sourced to the same model code. Quotations follow a review of the instruments to be calibrated, their ranges and accuracy classes, and the certificate requirements of the quality system.

Measuring instrument on a laboratory bench
Measuring instrument on a laboratory bench · ISATIS editorial illustration

Additel product families we supply

  • 01ADT760 and ADT762 automatic handheld pressure calibrators
  • 02Pressure controllers and pressure calibrators
  • 03Digital pressure gauges, pressure modules and readouts
  • 04Hand and electric pressure test pumps
  • 05Dry well calibrators and baths, including the 878 reference series
  • 06Temperature probes and readouts
  • 07Multifunction process calibrators and calibration software

Typical applications

  • 1Field calibration of pressure transmitters and gauges
  • 2Temperature sensor and transmitter checks in process plants
  • 3Calibration laboratories in refineries and power plants
  • 4Loop checks and commissioning of instrumentation

Buying guides for this equipment

FAQ

Common questions about Additel.

Is Additel calibration traceable?

Additel operates an ISO/IEC 17025 laboratory in Brea, California, accredited by NVLAP under lab code 600214-0. Instruments can be supplied with a calibration certificate traceable to national standards.

How do I select the right Additel pressure calibrator?

Start from the ranges and accuracy classes of the instruments under test, the pressure type (gauge, absolute or differential) and the medium. The reference should be clearly more accurate than the device it checks.

What do you need to quote an Additel calibrator?

A list of the instruments to be calibrated with their ranges and accuracy, the preferred model if known, any options such as HART or extra pressure modules, and the certificate type required.

Test & calibration

Other brands in this discipline.

All brands
  • Fluke logo
  • Beamex logo
  • Druck logo
  • Martel Electronics logo
  • Isotech logo
  • Elcometer logo
  • Dakota NDT logo
  • Megger logo
  • Testo logo
  • Hioki logo
  • Chauvin Arnoux logo
  • Keysight logo
  • Tektronix logo
  • FLIR logo

Send us your datasheets, P&IDs or tender documents.

We review them and reply with a technical and commercial proposal.

info@iow.ir +98 21 2205 5712 Request a quote