A 24 V marking alone does not identify a replacement solenoid coil. Match AC or DC supply, coil code, connector and fit to the installed valve.
If the reported problem concerns the electrical operator, keep the coil-only price separate from the complete solenoid valve. The body code and the installed coil must remain traceable to each other.
Read the full coil label
Record voltage, AC or DC, frequency where applicable and connection type. Establish whether the offer includes the plug, retainer or core-tube assembly, or the winding alone. Connector appearance does not establish compatibility.
Two 24-volt units in the same workshop
One coil may be 24 V DC and the other 24 V AC. Dropping those final letters creates an ambiguous stock item. Keep the body reference and a photograph of the coil label on the same enquiry line.
Enquiry checklist
| Item | What to record |
|---|---|
| Body | Complete valve code and series. |
| Coil | Voltage, current type and identifier. |
| Accessories | Plug, seals and separately required parts. |
Check the quotation Ask for the offered valve symbol and full order code beside the installed one. If a coil, connector or sub-base is priced separately, list it as a separate quotation line.
Tell ISATIS whether the comparison is coil-only or for the complete operator. For equipment in a classified area, include the project-approved assembly requirements.
Sample enquiry to ISATIS
Please identify a replacement coil for the body on the attached plate. List the coil, plug and associated parts separately and state voltage and current type for the quoted code.