Define gear pump rotation from a stated viewing side and identify both ports. A displacement and speed example checks theoretical flow independently.
Clockwise is ambiguous unless the observer's position is stated. Use the manufacturer's drawing to identify the viewing end, port arrangement, drive shaft and displacement of the existing gear pump.
Put a viewpoint on the sketch
Mark the shaft end and show the inlet and outlet using the equipment record. Also give flange, shaft dimensions, displacement and operating speed. Compare continuous operating conditions with the proposed rating.
A quick displacement check
At 10 cm³ per revolution and 1,500 rpm, theoretical flow is 15 L/min. Actual delivery is affected by volumetric losses. This calculation cannot establish rotation, port compatibility or real delivered flow under load.
Enquiry checklist
| Item | What to record |
|---|---|
| Rotation | Named viewing end and direction. |
| Geometry | Flange, shaft and port arrangement. |
| Duty | Displacement, speed and operating conditions. |
Check the quotation Ask for the drawing revision used to identify the spare, with the offered item number marked. Use the same numbered position when comparing a complete assembly with a repair kit.
Request an outline drawing of the offered pump with rotation clearly marked. Check it against the same viewing convention used for the installed unit.
Sample enquiry to ISATIS
Please quote a gear pump for the attached shaft-end view. Confirm displacement, rotation convention, port positions and rated duty.