Match a cartridge mechanical seal by shaft diameter, gland bolt pattern and axial space. Use the installation drawing to compare it with the existing pump.
A shaft diameter does not fully define a pump seal. The seal chamber, gland and mounting arrangement can differ between pumps using shafts of the same size.
Identify the assembly boundary
Provide the pump serial number, seal code and relevant chamber drawing. Record shaft or sleeve diameter, gland interface, service fluid and operating conditions. A request for faces and seals is different from a complete cartridge.
When the new gland will not fit
A proposed cartridge may have the right sleeve bore but different gland bolt spacing or axial length. Compare the installation drawing before treating it as a drop-in replacement.
Enquiry checklist
| Item | What to record |
|---|---|
| Pump | Model, serial and seal chamber drawing. |
| Interface | Shaft or sleeve, gland and axial dimensions. |
| Scope | Cartridge, internals or identified service kit. |
Check the quotation Ask for the drawing revision used to identify the spare, with the offered item number marked. Use the same numbered position when comparing a complete assembly with a repair kit.
Have any changes in materials or flush arrangement marked on the proposal for engineering review.
Sample enquiry to ISATIS
Please quote the specified mechanical seal and identify its supply boundary. Provide the gland drawing, materials and any differences from the installed assembly.