Compare the centre-position spool symbol before replacing a hydraulic directional valve. Two valves can fit the same subplate and connect different ports.
A valve can fit the same subplate and still connect its ports differently in the centre position. The full spool symbol is a purchasing reference because it determines how the machine circuit behaves.
Read the approved circuit drawing
Record the valve code, port pattern, actuation method, coil specification and spool symbol. Mark the normal and centre positions on the reference drawing. Resolve discrepancies between the drawing and the installed nameplate with the responsible engineer.
A matching footprint with a different centre
Two valves may share mounting holes and port designations. One spool connects ports in the centre that the other closes. A similar footprint does not make this a routine substitution.
Enquiry checklist
| Item | What to record |
|---|---|
| Circuit | Approved spool symbol and drawing revision. |
| Mount | Subplate pattern and port identification. |
| Actuation | Voltage, connector and return arrangement. |
Check the quotation Ask for the offered valve symbol and full order code beside the installed one. If a coil, connector or sub-base is priced separately, list it as a separate quotation line.
Ask for the offered symbol alongside the order code. Any change in port connections belongs in machine design review before purchase.
Sample enquiry to ISATIS
Please quote the valve matching the attached hydraulic symbol. Identify the complete spool code, subplate interface and coil specification.