Compare 1,000 µF, 450 V DC-link capacitors by ripple current, terminal spacing and fit. Matching capacitance and voltage is only the first check.
Capacitance and voltage identify only part of a DC-link capacitor. Check the original series and duty, ripple-current limits, temperature basis, service life conditions and mechanical interface.
Read the conditions beside the rating
Record the operating frequency and temperature at which ripple current is specified. Compare ESR and heat dissipation where relevant, and check diameter, height, terminal arrangement and spacing against the approved equipment record.
Two 1,000 µF, 450 V capacitors
Both meet the two headline values. One may have a lower allowable ripple current at the relevant temperature or a different bolt spacing. Either difference can rule out a direct replacement.
Enquiry checklist
| Item | What to record |
|---|---|
| Electrical | Capacitance, voltage and series. |
| Thermal | Ripple limit, frequency and temperature basis. |
| Fit | Dimensions, terminal style and spacing. |
Check the quotation State the load during normal operation and during the most demanding part of the duty cycle separately. Ask which of these conditions determines the offered rating.
Request a comparison of the exact offered series with the original. Refer uncertain substitutions to the equipment engineer.
Sample enquiry to ISATIS
Please quote the DC-link capacitor against the attached part marking. State ripple-current conditions, ESR basis and terminal dimensions.