Specify a clamp-on flowmeter using pipe outside diameter, wall thickness and lining. A 114 mm pipe example shows how to establish the internal diameter.
Nominal pipe size alone does not describe the acoustic path. Give the actual outside diameter, wall thickness and any lining separately when requesting a clamp-on meter.
Distinguish the drawing from the installed pipe
Pipes with the same nominal size can have different wall thicknesses. Record pipe material, lining and surface condition at the proposed mounting position. Mark whether a value was measured on site or taken from a drawing so a design assumption is not mistaken for a field measurement.
From outside diameter to an initial bore check
For an unlined pipe with a 114 mm outside diameter and a 6 mm wall on each side, the geometric inside diameter is approximately 102 mm. With a lining, that calculation alone defines neither the flow bore nor the full acoustic path.
Enquiry checklist
| Item | What to record |
|---|---|
| Pipe | Actual outside diameter, wall thickness and material, with units. |
| Location | Accessible straight length, clearance and obstructions. |
| Fluid | Fluid identity, temperature and expected flow range. |
Check the quotation Send the line tag and mark exactly which item is being replaced on the existing meter drawing. Ask the bidder to identify any change to installation dimensions or to the signal used by the control system.
Compare transducer type, mounting method and clamp accessories. A photograph without a scale or wall data cannot replace dimensional information.
Sample enquiry to ISATIS
Please propose transducers and mounting hardware for the attached line. Outside diameter, wall thickness and lining details are listed separately. Identify any selection assumptions.